Acute thrombosis of prosthetic valves: a multivariate analysis of the risk factors for a lifethreatening event
- PMID: 1389247
- DOI: 10.1016/1010-7940(92)90065-6
Acute thrombosis of prosthetic valves: a multivariate analysis of the risk factors for a lifethreatening event
Abstract
In 3231 prosthetic valves implanted between January 1975 and November 1990, we observed 61 cases of prosthetic obstruction of biological origin with clinical and laboratory findings of severe functional impairment which required surgery as emergency treatment. The hospital mortality was 19.67% (12/61). The obstruction was due to a primary thrombosis in all 5 bioprostheses which were not anticoagulated and in 11/56 (19.64%) mechanical prostheses of which 3 were not anticoagulated and 4 were not properly anticoagulated. The obstruction was due to fibrous tissue overgrowth in the other 45 mechanical prostheses (80.35%) with secondary thrombosis in 34 cases (60.71%) and no thrombosis in 11 (19.64%); 71.11% of these prostheses were adequately anticoagulated. Of the 61 obstructed prostheses, 53 were mitral and 8 were aortic. No tricuspid obstruction was observed. A statistical assessment by multiple correspondence, cluster and chi square analysis was performed in two groups of patients with different models of mechanical mitral prostheses. The 5-year actuarial incidence of obstruction was 6.08%. Significant risk factors were: tilting disc prostheses, prostheses without pyrocarbon coating, large prostheses, tilting disc prostheses with a small orifice posteriorly oriented, atrial fibrillation, enlarged left atrium, time from implant greater than 4 years, age between 40 and 50 years. In our opinion, prosthetic obstruction may be referred to a primary thrombosis only in cases where it may be prevented by adequate anticoagulation. In most cases, the obstruction is produced by periprosthetic fibroblastic proliferation which may develop in spite of adequate anticoagulation in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and risk.Eur J Cardiothorac Surg. 1999 Jul;16(1):74-80. doi: 10.1016/s1010-7940(99)00124-4. Eur J Cardiothorac Surg. 1999. PMID: 10456407
-
Which type of valve should we use in tricuspid position? Long-term comparison between mechanical and biological valves.J Cardiovasc Surg (Torino). 2017 Oct;58(5):739-746. doi: 10.23736/S0021-9509.16.09553-7. Epub 2016 Sep 16. J Cardiovasc Surg (Torino). 2017. PMID: 27636399
-
[Long-term follow-up of aortic or mitral valve replacement. Comparison of results following implantation of a mechanical or biological artificial valve].Herz. 1986 Apr;11(2):97-115. Herz. 1986. PMID: 3699678 German.
-
Prosthetic heart valves: a review.Prog Cardiovasc Dis. 1983 Nov-Dec;26(3):237-70. doi: 10.1016/0033-0620(83)90008-7. Prog Cardiovasc Dis. 1983. PMID: 6359270 Review.
-
Mechanical and surgical bioprosthetic valve thrombosis.Heart. 2017 Dec;103(24):1934-1941. doi: 10.1136/heartjnl-2017-311856. Epub 2017 Aug 5. Heart. 2017. PMID: 28780576 Review.
Cited by
-
Obstruction of the left ventricular outflow tract due to pannus formation after the implantation of a carbomedics aortic valve.Jpn J Thorac Cardiovasc Surg. 2006 Jul;54(7):304-7. doi: 10.1007/pl00022259. Jpn J Thorac Cardiovasc Surg. 2006. PMID: 16898646
-
Validation of large animal models in mechanical valve research: a histologic comparison.Interdiscip Cardiovasc Thorac Surg. 2024 May 2;38(5):ivae070. doi: 10.1093/icvts/ivae070. Interdiscip Cardiovasc Thorac Surg. 2024. PMID: 38637938 Free PMC article.
-
Subvalvular Pannus Overgrowth after Mosaic Bioprosthesis Implantation in the Aortic Position.Ann Thorac Cardiovasc Surg. 2016;22(2):108-11. doi: 10.5761/atcs.oa.15-00293. Epub 2015 Dec 2. Ann Thorac Cardiovasc Surg. 2016. PMID: 26633541 Free PMC article.
-
Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation.J Artif Organs. 2005;8(4):270-3. doi: 10.1007/s10047-005-0317-9. J Artif Organs. 2005. PMID: 16362526
-
Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.J Artif Organs. 2006;9(3):199-202. doi: 10.1007/s10047-006-0334-3. J Artif Organs. 2006. PMID: 16998706
MeSH terms
LinkOut - more resources
Full Text Sources
Medical