Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves
- PMID: 1389286
Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves
Abstract
Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
The stentless bioprosthesis: surgical challenges and implications for long-term durability.Eur J Cardiothorac Surg. 1992;6 Suppl 1:S39-42; discussion S43. Eur J Cardiothorac Surg. 1992. PMID: 1389277 Review.
-
Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves.J Thorac Cardiovasc Surg. 1993 Jan;105(1):154-64. J Thorac Cardiovasc Surg. 1993. PMID: 8419696
-
Low-profile porcine bioprosthesis (Liotta): pathologic findings and mode of failure in the long-term.J Heart Valve Dis. 1996 May;5(3):323-7. J Heart Valve Dis. 1996. PMID: 8793685
-
Pathology of the Pericarbon bovine pericardial xenograft implanted in humans.J Heart Valve Dis. 1998 Mar;7(2):180-9. J Heart Valve Dis. 1998. PMID: 9587859
-
Research on biological and mechanical heart valves: experimental studies in chronic animal models.Verh K Acad Geneeskd Belg. 2002;64(4):287-302. Verh K Acad Geneeskd Belg. 2002. PMID: 12416236 Review.
Cited by
-
Design and Testing of a Pulsatile Conditioning System for Dynamic Endothelialization of Polyphenol-Stabilized Tissue Engineered Heart Valves.Cardiovasc Eng Technol. 2010 Jun;1(2):138-153. doi: 10.1007/s13239-010-0014-6. Cardiovasc Eng Technol. 2010. PMID: 21340043 Free PMC article.
-
Evaluation of hemolysis in patients with prosthetic heart valves.Clin Cardiol. 1998 Jun;21(6):387-92. doi: 10.1002/clc.4960210604. Clin Cardiol. 1998. PMID: 9631266 Free PMC article. Review.
-
Screening biomaterials with a new in vitro method for potential calcification: porcine aortic valves and bovine pericardium.J Mater Sci Mater Med. 2004 Jun;15(6):699-704. doi: 10.1023/b:jmsm.0000030212.55320.c2. J Mater Sci Mater Med. 2004. PMID: 15346738