Complications of Mersilene sutures in penetrating keratoplasty
- PMID: 1390410
Complications of Mersilene sutures in penetrating keratoplasty
Abstract
Background: After penetrating keratoplasty, many corneal surgeons adjust sutures to reduce astigmatism and then leave the sutures in place indefinitely. Nylon sutures can hydrolyze and break years after surgery. In a series of human penetrating keratoplasties, we studied the use of polyester (Mersilene) sutures that do not hydrolyze.
Methods: We performed two prospective studies of polyester (Mersilene) sutures in human penetrating keratoplasty done by one surgeon. Study I was a randomized comparison of combined running and interrupted Mersilene and nylon sutures in 45 consecutive eyes. Study II was a case series of single running Mersilene suture with postoperative adjustment of suture tension to manage astigmatism in 23 consecutive eyes. We evaluated the performance of the suture and the control of astigmatism.
Results: The interrupted running suture study demonstrated that interrupted Mersilene sutures were 5.5 times more likely to have handling-related complications than nylon interrupted sutures (p = .01); in addition, they were three times as likely to have tissue-related complications as nylon (p = .16). The running suture study demonstrated an unacceptable complication rate of 69% when Mersilene was used as a single adjustable running suture. At 6 months postoperatively, the median refractive astigmatism for the adjustable cases was 3.37 diopters (mean, 4.03 +/- 2.37 D). Eyes with significant suture-related complications were 2.85 times more likely to have greater than 4.00 D of refractive astigmatism than were eyes without suture-related complications.
Conclusions: Mersilene is an undesirable suture for use in penetrating keratoplasty.
Similar articles
-
Inadequacy of a polyester (Mersilene) suture for the reduction of astigmatism after penetrating keratoplasty.Trans Am Ophthalmol Soc. 1990;88:237-49; discussion 249-54. Trans Am Ophthalmol Soc. 1990. PMID: 2095023 Free PMC article. Clinical Trial.
-
Astigmatism after mersilene and nylon suture use for penetrating keratoplasty.Cornea. 2006 Jul;25(6):691-4. doi: 10.1097/01.ico.0000208821.32614.49. Cornea. 2006. PMID: 17077662
-
Comparison of complication rates and postoperative astigmatism between nylon and mersilene sutures for corneal transplants in patients with Fuchs endothelial dystrophy.Cornea. 2006 Jun;25(5):533-9. doi: 10.1097/01.ico.0000214218.60249.e5. Cornea. 2006. PMID: 16783141
-
Management of post-keratoplasty astigmatism.J Cataract Refract Surg. 2012 Nov;38(11):2029-39. doi: 10.1016/j.jcrs.2012.09.002. J Cataract Refract Surg. 2012. PMID: 23079317 Review.
-
Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation.J Clin Med. 2023 May 14;12(10):3462. doi: 10.3390/jcm12103462. J Clin Med. 2023. PMID: 37240568 Free PMC article. Review.
Cited by
-
Update on Suture Techniques in Corneal Transplantation: A Systematic Review.J Clin Med. 2022 Feb 18;11(4):1078. doi: 10.3390/jcm11041078. J Clin Med. 2022. PMID: 35207352 Free PMC article. Review.