Comparative Study
. 1992 Oct;20(10):1426-30.
doi: 10.1097/00003246-199210000-00011.

Infectious and mechanical complications of central venous catheters placed by percutaneous venipuncture and over guidewires

Affiliations
Comparative Study

Infectious and mechanical complications of central venous catheters placed by percutaneous venipuncture and over guidewires

M T Hagley et al. Crit Care Med. 1992 Oct.

Abstract

Objective: To compare the frequency of infectious and mechanical complications of central venous and pulmonary artery catheters placed by initial venipuncture vs. over a guidewire at existing sites.

Hypothesis: Exchange of central venous catheters and pulmonary artery catheters over a guidewire as opposed to fresh venipuncture reduces mechanical complications without increasing risk of infection.

Design: Chart audit.

Patients: Medical, surgical, and coronary ICU patients requiring invasive monitoring or central venous access.

Interventions: Patients requiring prolonged catheterization underwent periodic exchange of catheters over a guidewire. Rates of catheter-related infections and mechanical complications were determined for central venous catheters placed by initial venipuncture and those catheters placed by guidewire exchange.

Measurements and main results: Over a 12-month period, 939 catheters were inserted in 454 patients. Of these 939 catheters, 534 were placed by guidewire exchange. Use of a guidewire was associated with a decreased frequency of pneumothorax and hemothorax compared with initial venipuncture (0/405 [0%] vs. 7/534 [1.3%], respectively; p < .05) but not with increased risk of infection (9/405 [2.2%] vs. 14/534 [2.6%], respectively; NS). Guidewire-facilitated replacement of multiple consecutive catheters at the same site did not increase the risk of catheter-related infection. Catheters placed via internal jugular veins were more likely to become infected than catheters placed via subclavian veins (17/477 [3.6%] vs. 3/430 [0.7%], respectively; p < .01).

Conclusions: When prolonged central venous or pulmonary artery catheterization is necessary, periodic catheter replacement over a guidewire is associated with fewer mechanical complications than initial venipuncture. Periodic catheter replacement over a guidewire is also associated with no increase in risk of infection.