Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor
- PMID: 1396876
- DOI: 10.1007/BF00182823
Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor
Abstract
The accuracy and repeatability of a new ambulatory radionuclide detector (VEST) for left ventricular systolic (ejection fraction) and diastolic (peak filling rate) measurements were assessed. Seventeen patients underwent equilibrium radionuclide angiography immediately before and immediately after a VEST study. The accuracy was evaluated at the beginning and at the end of the VEST studies. Limits of agreement for the ejection fraction were -1%:2% at the beginning of the VEST study and -4%:4% at the end. Limits of agreement for the peak filling rate were -0.6:0.6 at the beginning of the VEST study and -0.7:0.5 at the end. For both measurements the limits of agreement were well within the clinical range. Repeatability was evaluated in a second group of 11 patients who underwent VEST studies in 2 separate days. The coefficient of repeatability (twice the standard deviation of the differences between the 2 studies) was 13 for the ejection fraction and 0.4 for the peak filling rate. Thus, the VEST is an accurate and repeatable method to measure both the ejection fraction and peak filling rate.
Similar articles
-
Left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor: effects of different time averaging on accuracy.J Nucl Med. 1993 Sep;34(9):1602-6. J Nucl Med. 1993. PMID: 8355081
-
Continuous ambulatory radionuclide monitoring of left ventricular function: effect of body position during ergometer exercise.J Nucl Med. 1997 Nov;38(11):1669-72. J Nucl Med. 1997. PMID: 9374329
-
Clinical evaluation of cardiac function by ambulatory ventricular scintigraphic monitoring (VEST): validation and study of the effects of nitroglycerin and nifedipine in patients with and without coronary artery disease.Am Heart J. 1992 Feb;123(2):386-94. doi: 10.1016/0002-8703(92)90650-k. Am Heart J. 1992. PMID: 1736574
-
Myocardial dysfunction in silent myocardial ischemia as demonstrated by ambulatory radionuclide left ventricular function studies.Cardiol Clin. 1992 Aug;10(3):473-8. Cardiol Clin. 1992. PMID: 1504978 Review.
-
Ventricular responses to mental stress testing in patients with coronary artery disease. Pathophysiological implications.Circulation. 1991 Apr;83(4 Suppl):II137-44. Circulation. 1991. PMID: 2009621 Review.
Cited by
-
Early and late effects of coronary artery bypass grafting on cardiac haemodynamics during daily physical activities in patients with coronary artery disease.Eur J Nucl Med Mol Imaging. 2004 Jun;31(6):852-6. doi: 10.1007/s00259-004-1456-6. Epub 2004 Feb 3. Eur J Nucl Med Mol Imaging. 2004. PMID: 14758512 Clinical Trial.
-
EANM/ESC guidelines for radionuclide imaging of cardiac function.Eur J Nucl Med Mol Imaging. 2008 Apr;35(4):851-85. doi: 10.1007/s00259-007-0694-9. Eur J Nucl Med Mol Imaging. 2008. PMID: 18224320
-
Hemodynamic effects of isometric exercise in hypertrophic cardiomyopathy: comparison with normal subjects.J Nucl Cardiol. 2003 Mar-Apr;10(2):154-60. doi: 10.1067/mnc.2003.9. J Nucl Cardiol. 2003. PMID: 12673180 Clinical Trial.
-
Assessment of left ventricular volume by an ambulatory radionuclide monitoring system during head-up tilt in patients with unexplained syncope: relation to autonomic activity assessed by heart rate variability.J Nucl Cardiol. 2001 Nov-Dec;8(6):660-8. doi: 10.1067/mnc.2001.116496. J Nucl Cardiol. 2001. PMID: 11725262 Clinical Trial.
-
Radionuclide monitoring of left ventricular function after sublingual nifedipine administration at rest and during moderate physical activity.J Nucl Cardiol. 2001 Nov-Dec;8(6):669-76. doi: 10.1067/mnc.2001.118070. J Nucl Cardiol. 2001. PMID: 11725263 Clinical Trial.