Comparison of technetium-99m sestamibi and thallium-201 retention characteristics in canine myocardium
- PMID: 1401632
- DOI: 10.1016/0735-1097(92)90388-4
Comparison of technetium-99m sestamibi and thallium-201 retention characteristics in canine myocardium
Abstract
Objectives: The aim of this study was to compare the myocardial retention of technetium-99m (Tc-99m) sestamibi and thallium-201 over a wide range of blood flow at different time points after tracer injection.
Background: Technetium-99m sestamibi has been proposed as a new perfusion tracer with better physical characteristics than those of thallium-201 for scintigraphic imaging. However, no studies have simultaneously compared the ability of both tracers to assess myocardial blood flow during pharmacologic vasodilation.
Methods: The myocardial retention of Tc-99m sestamibi and thallium-201 were compared over a wide range of blood flow induced by regional coronary occlusion and dipyridamole infusion in an open chest dog model. Myocardial retention of both tracers was determined by in vitro tissue counting at 2, 5, and 20 min after tracer injection and was correlated with microsphere-determined blood flow.
Results: Thallium-201 demonstrated greater absolute tissue retention than did Tc-99m sestamibi. At 2 min after tracer injection, there was an almost linear relation between the retention of both tracers and myocardial blood flow over a wide flow range. However, this relation was not maintained over time. At 20 min after injection, the retention of both tracers underestimated myocardial blood flow at higher flow rates. At 2, 5 and 20 min after injection, increments of relative tracer retention between the different levels of flow were always greater for thallium-201 than for Tc-99m sestamibi.
Conclusions: Thallium-201 displays more suitable physiologic characteristics as a flow tracer and may allow better differentiation of myocardial regions with different levels of coronary flow reserve. For both tracers, early cardiac imaging may minimize underestimation of blood flow at higher flow rates.
Comment in
-
Sestamibi in myocardial perfusion imaging.J Am Coll Cardiol. 1993 Aug;22(2):632. doi: 10.1016/0735-1097(93)90079-g. J Am Coll Cardiol. 1993. PMID: 8335842 No abstract available.
Similar articles
-
Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.JACC Cardiovasc Imaging. 2009 Oct;2(10):1198-208. doi: 10.1016/j.jcmg.2009.06.013. JACC Cardiovasc Imaging. 2009. PMID: 19833310
-
Comparison of single-photon emission computed tomographic (SPECT) myocardial perfusion imaging with thallium-201 and technetium-99m sestamibi in dogs.J Am Coll Cardiol. 1992 Dec;20(7):1612-25. doi: 10.1016/0735-1097(92)90458-y. J Am Coll Cardiol. 1992. PMID: 1452936
-
The relationship between myocardial retention of technetium-99m teboroxime and myocardial blood flow.J Am Coll Cardiol. 1992 Sep;20(3):712-9. doi: 10.1016/0735-1097(92)90029-m. J Am Coll Cardiol. 1992. PMID: 1512353
-
Experimental studies of the physiologic properties of technetium-99m agents: myocardial transport of perfusion imaging agents.Am J Cardiol. 1990 Oct 16;66(13):9E-15E. doi: 10.1016/0002-9149(90)90606-2. Am J Cardiol. 1990. PMID: 2145753 Review.
-
Experimental studies of the physiologic properties of technetium-99m isonitriles.Am J Cardiol. 1990 Oct 16;66(13):5E-8E. doi: 10.1016/0002-9149(90)90605-z. Am J Cardiol. 1990. PMID: 2145747 Review.
Cited by
-
Comparison of myocardial contrast echocardiography with NC100100 and (99m)Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction.Heart. 2000 May;83(5):518-24. doi: 10.1136/heart.83.5.518. Heart. 2000. PMID: 10768900 Free PMC article. Clinical Trial.
-
Myocardial kinetics of radiolabeled perfusion agents: basis for perfusion imaging.J Nucl Cardiol. 1994 Mar-Apr;1(2 Pt 1):189-97. doi: 10.1007/BF02984091. J Nucl Cardiol. 1994. PMID: 9420686 Review.
-
Myocardial perfusion imaging: clinical experience and recent progress in radionuclide scintigraphy and magnetic resonance imaging.Int J Card Imaging. 1997 Oct;13(5):415-31. doi: 10.1023/a:1005737725964. Int J Card Imaging. 1997. PMID: 9360178 Review.
-
Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.J Nucl Cardiol. 1996 Nov-Dec;3(6 Pt 1):483-93. doi: 10.1016/s1071-3581(96)90058-6. J Nucl Cardiol. 1996. PMID: 8989673
-
Optimization of flow reserve measurement using SPECT technology to evaluate the determinants of coronary microvascular dysfunction in diabetes.Eur J Nucl Med Mol Imaging. 2010 Feb;37(2):357-67. doi: 10.1007/s00259-009-1316-5. Epub 2009 Dec 3. Eur J Nucl Med Mol Imaging. 2010. PMID: 19957177
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources