Use of magnetic resonance imaging to analyze the performance of hollow-fiber bioreactors
- PMID: 1416611
- DOI: 10.1111/j.1749-6632.1992.tb42592.x
Use of magnetic resonance imaging to analyze the performance of hollow-fiber bioreactors
Abstract
Preliminary experiments were described that demonstrate that MRI is an effective tool for the noninvasive study of hollow-fiber bioreactors. Flow-compensated velocity-encoding pulse sequences were successively applied to analyze the velocity patterns in a module operated without cells, with an artificially induced flow field perturbation. Diffusion damping pulse sequences were also used to spatially resolve regions of cell growth in a bioreactor. These experiments provide the necessary basis from which future flow and spectroscopic studies can be conducted.
Similar articles
-
Controlling and predicting monoclonal antibody production in hollow-fiber bioreactors.Enzyme Microb Technol. 1992 Jan;14(1):58-63. doi: 10.1016/0141-0229(92)90027-l. Enzyme Microb Technol. 1992. PMID: 1367811
-
A continuous perfusion bioreactor for long-term bone marrow culture.Ann N Y Acad Sci. 1992 Oct 13;665:274-84. doi: 10.1111/j.1749-6632.1992.tb42591.x. Ann N Y Acad Sci. 1992. PMID: 1416610 No abstract available.
-
The role of bioreactors in tissue engineering.Trends Biotechnol. 2004 Feb;22(2):80-6. doi: 10.1016/j.tibtech.2003.12.001. Trends Biotechnol. 2004. PMID: 14757042 Review.
-
Immobilized animal cell bioreactors.Bioprocess Technol. 1995;21:377-411. Bioprocess Technol. 1995. PMID: 7765642 Review. No abstract available.
-
Bioreactor design for insect cell cultivation: a review.Bioprocess Technol. 1993;17:51-68. Bioprocess Technol. 1993. PMID: 7763509 Review. No abstract available.
Cited by
-
Imaging glucose metabolism in perfluorocarbon-perfused hepatocyte bioreactors using positron emission tomography.J Artif Organs. 2009;12(4):247-57. doi: 10.1007/s10047-009-0480-5. Epub 2009 Dec 25. J Artif Organs. 2009. PMID: 20035398
-
New advances in MR-compatible bioartificial liver.NMR Biomed. 2012 Mar;25(3):427-42. doi: 10.1002/nbm.1633. Epub 2011 Feb 20. NMR Biomed. 2012. PMID: 22351642 Free PMC article. Review.
-
Bioreactor design and validation for manufacturing strategies in tissue engineering.Biodes Manuf. 2022 Jan;5(1):43-63. doi: 10.1007/s42242-021-00154-3. Epub 2021 Jul 19. Biodes Manuf. 2022. PMID: 35223131 Free PMC article.
-
Analysis of CHO-K1 cell growth in a fixed bed bioreactor using magnetic resonance spectroscopy and imaging.Cytotechnology. 1999 Jul;30(1-3):121-32. doi: 10.1023/A:1008039011960. Cytotechnology. 1999. PMID: 19003361 Free PMC article.
-
Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models.Concepts Magn Reson Part B Magn Reson Eng. 2011 Aug;39B(3):149-158. doi: 10.1002/cmr.b.20202. Concepts Magn Reson Part B Magn Reson Eng. 2011. PMID: 26167136 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources