Quantitative precision of an automated, fluorescence-based image cytometer
- PMID: 1418268
Quantitative precision of an automated, fluorescence-based image cytometer
Abstract
Digital image-based cytometry of clinical specimens labeled with fluorescent, disease-specific markers holds promise for becoming an important diagnostic and prognostic technique because the technique can make a diverse range of quantitative biochemical, morphologic, densitometric and contextual measurements on intact specimens. It has been previously shown by us, using an image cytometer (IC) consisting entirely of commercially available components, that the nuclei of individual cells in slide-supported specimens can be detected automatically using a fluorescent DNA stain and image analysis software. The purpose of this study was to determine the precision of the IC for quantifying the integrated fluorescence intensity and area of fluorescent standard beads and nuclei. Integrated intensities could be quantified to between 2.3% and 3.5% precision using a 40x objective lens and between 1.6% and 2.3% using a 20x objective. The main contribution to this uncertainty was 2% inaccuracy in determining the variations in sensitivity over the imaging area. Areas could be quantified to between 0.91% and 2.1% using a 40x objective and between 2.8% and 3.2% using a 20x objective. Significant quantification errors were introduced if the objects were not in focus or were touching each other. Overall, however, these results demonstrated that image cytometry of fluorescence-stained specimens can yield quantitative results with sufficient precision for determining DNA ploidy distributions and for making other measurements on clinical specimens.
Similar articles
-
Automated fluorescence image cytometry. DNA quantification and detection of chlamydial infections.Anal Quant Cytol Histol. 1991 Feb;13(1):27-44. Anal Quant Cytol Histol. 1991. PMID: 2025371
-
Automated image-based cytometry with fluorescence-stained specimens.Biotechniques. 1991 Apr;10(4):514-9. Biotechniques. 1991. PMID: 1867861
-
Automatic detection of clustered, fluorescent-stained nuclei by digital image-based cytometry.Cytometry. 1994 Sep 1;17(1):1-12. doi: 10.1002/cyto.990170102. Cytometry. 1994. PMID: 7528121
-
Consensus report of the European Society for Analytical Cellular Pathology task force on standardization of diagnostic DNA image cytometry.Anal Quant Cytol Histol. 1995 Feb;17(1):1-7. Anal Quant Cytol Histol. 1995. PMID: 7766264 Review. No abstract available.
-
Fluorescent stains for quantification of DNA by confocal laser scanning microscopy in 3-D.Biotech Histochem. 2008 Apr;83(2):63-9. doi: 10.1080/10520290802127586. Biotech Histochem. 2008. PMID: 18568680 Review.
Cited by
-
Introduction to the quantitative analysis of two-dimensional fluorescence microscopy images for cell-based screening.PLoS Comput Biol. 2009 Dec;5(12):e1000603. doi: 10.1371/journal.pcbi.1000603. Epub 2009 Dec 24. PLoS Comput Biol. 2009. PMID: 20041172 Free PMC article. No abstract available.
-
CellProfiler: image analysis software for identifying and quantifying cell phenotypes.Genome Biol. 2006;7(10):R100. doi: 10.1186/gb-2006-7-10-r100. Epub 2006 Oct 31. Genome Biol. 2006. PMID: 17076895 Free PMC article.
-
How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards.J Fluoresc. 2005 May;15(3):337-62. doi: 10.1007/s10895-005-2630-3. J Fluoresc. 2005. PMID: 15986157
-
Ploidy analysis on Wilms' tumour touch imprints using ethidium bromide and automated image analysis integrated confocal laser scanning microscopy.Virchows Arch. 1995;427(1):101-4. doi: 10.1007/BF00203744. Virchows Arch. 1995. PMID: 7551338
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Other Literature Sources