Comparison of Doppler echocardiography and cardiac catheterization in patients requiring valve surgery: search for a 'gold standard'
- PMID: 1423004
Comparison of Doppler echocardiography and cardiac catheterization in patients requiring valve surgery: search for a 'gold standard'
Abstract
Objective: To compare the sensitivities of Doppler echocardiography and cardiac catheterization in the diagnosis of severe valvular heart disease in patients requiring valve surgery.
Design: Retrospective analysis of Doppler echocardiograms and cardiac catheterizations.
Setting: Tertiary referral cardiovascular centre in a university setting.
Patients: Sixty-nine patients undergoing valve surgery between July 1988 and July 1990.
Results: The sensitivities of echocardiography and cardiac catheterization were 84 and 87%, respectively (P = 1.0) in 32 patients who underwent aortic valve surgery primarily for severe aortic stenosis; 83 and 67%, respectively (P = 1.0) in six patients with severe aortic regurgitation, and 100 and 85%, respectively (P = 1.0) in seven patients with combined severe aortic stenosis and regurgitation. The sensitivities of echocardiography and cardiac catheterization in 11 patients who underwent mitral valve surgery for severe mitral stenosis were 73 and 91%, respectively (P = 0.6) and 69 and 92%, respectively (P = 0.3) in 13 patients with severe mitral regurgitation. Sensitivities of echocardiography and cardiac catheterization in the diagnosis of severe tricuspid regurgitation in five patients who had tricuspid valve repair were 100 and 80%, respectively (P = 1.0). Two patients with severe aortic stenosis by echocardiography, but not by catheterization, did not undergo aortic valve replacement during valvular surgery; both required aortic valve replacement within two years of initial surgery because of heart failure. Four patients with severe tricuspid regurgitation identified by echocardiography did not have tricuspid repair; three had pulmonary hypertension and these patients had resolution of tricuspid regurgitation on follow-up. One patient with severe tricuspid regurgitation and absence of pulmonary hypertension required reoperation for tricuspid valve repair 10 months after initial operation.
Conclusions: The sensitivity of echocardiography and cardiac catheterization in the detection of severe valvular lesions requiring surgery is similar. Discordant results should be reviewed carefully with knowledge of the inherent pitfalls of both techniques in order to ensure optimal patient outcome.
Similar articles
-
Long-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.J Thorac Cardiovasc Surg. 1998 Oct;116(4):599-608. doi: 10.1016/S0022-5223(98)70166-7. J Thorac Cardiovasc Surg. 1998. PMID: 9766588
-
Hemodynamic characterization of the CarboMedics mitral valve prosthesis.J Heart Valve Dis. 1997 Mar;6(2):115-22. J Heart Valve Dis. 1997. PMID: 9130117 Clinical Trial.
-
Repair of nonsevere rheumatic aortic valve disease during other valvular procedures: is it safe?J Thorac Cardiovasc Surg. 1998 May;115(5):1130-5. doi: 10.1016/S0022-5223(98)70413-1. J Thorac Cardiovasc Surg. 1998. PMID: 9605083
-
[Exercise capacity after heart valve replacement].Z Kardiol. 1994;83 Suppl 3:111-20. Z Kardiol. 1994. PMID: 7941657 Review. German.
-
[The best of valvular heart disease in 2006].Arch Mal Coeur Vaiss. 2007 Jan;100 Spec No 1:19-28. Arch Mal Coeur Vaiss. 2007. PMID: 17405561 Review. French.
Publication types
MeSH terms
LinkOut - more resources
Medical