Intravascular stenting: from basic research to clinical application
- PMID: 1423387
- DOI: 10.1007/BF02733951
Intravascular stenting: from basic research to clinical application
Abstract
Although the use of intravascular stents is approaching widespread clinical use, several questions remain regarding their safety and efficacy. Several factors have direct bearing on the immediate and long-term results of intravascular stenting. The technical results of stenting are dependent on the mechanical characteristics of the device and long-term patency is closely related to thrombogenicity and endothelialization. Although stents are used most frequently for the treatment of atherosclerotic disease there is no clear understanding of how they influence the atheromatous lesion.
Similar articles
-
Use of intravascular ultrasound improves long-term clinical outcome in the endovascular management of atherosclerotic aortoiliac occlusive disease.J Vasc Surg. 1998 Apr;27(4):614-23. doi: 10.1016/s0741-5214(98)70225-3. J Vasc Surg. 1998. PMID: 9576073
-
Intravascular endoprostheses. Effect of surface geometry on restenosis and side branch patency.ASAIO Trans. 1989 Jul-Sep;35(3):376-8. doi: 10.1097/00002480-198907000-00066. ASAIO Trans. 1989. PMID: 2532030
-
Intravascular ultrasound scanning improves long-term patency of iliac lesions treated with balloon angioplasty and primary stenting.J Vasc Surg. 2002 Feb;35(2):316-23. doi: 10.1067/mva.2002.119755. J Vasc Surg. 2002. PMID: 11854730
-
Stents for atherosclerotic renovascular disease.J Vasc Interv Radiol. 1999 Jun;10(6):689-705. doi: 10.1016/s1051-0443(99)70103-x. J Vasc Interv Radiol. 1999. PMID: 10392936 Review.
-
Application of intravascular ultrasound in remodelling studies.Semin Interv Cardiol. 1997 Mar;2(1):11-8. Semin Interv Cardiol. 1997. PMID: 9546979 Review.
Cited by
-
Suitability of incorporated vascular stents for surgical patch-plasty: an experimental study.Cardiovasc Intervent Radiol. 1995 Jul-Aug;18(4):233-8. doi: 10.1007/BF00239418. Cardiovasc Intervent Radiol. 1995. PMID: 8581903
-
Late thromboembolic complication from a Palmaz stent in the common iliac artery.Cardiovasc Intervent Radiol. 1996 May-Jun;19(3):190-2. doi: 10.1007/BF02577619. Cardiovasc Intervent Radiol. 1996. PMID: 8661649
-
Coronary stent thrombosis: what have we learned?J Thorac Dis. 2016 Jul;8(7):1398-405. doi: 10.21037/jtd.2016.05.69. J Thorac Dis. 2016. PMID: 27500366 Free PMC article. No abstract available.
-
A nonlinear finite element simulation of balloon expandable stent for assessment of plaque vulnerability inside a stenotic artery.Med Biol Eng Comput. 2014 Jul;52(7):589-99. doi: 10.1007/s11517-014-1163-9. Epub 2014 Jun 3. Med Biol Eng Comput. 2014. PMID: 24888756
-
Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso.J Biomed Mater Res B Appl Biomater. 2020 Jul;108(5):2192-2203. doi: 10.1002/jbm.b.34557. Epub 2020 Jan 14. J Biomed Mater Res B Appl Biomater. 2020. PMID: 31943806 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources