Vasomotor response to ergometrine and nitrates of saphenous vein grafts, internal mammary artery grafts, and grafted coronary arteries late after bypass surgery
- PMID: 1424002
Vasomotor response to ergometrine and nitrates of saphenous vein grafts, internal mammary artery grafts, and grafted coronary arteries late after bypass surgery
Abstract
Background: In vitro studies have shown that the vasomotor response of internal mammary artery to vasoactive agents differs from that of saphenous vein.
Methods and results: To assess whether the response in vivo to methylergometrine and to nitrates differs in saphenous vein grafts, internal mammary artery grafts, and coronary arteries, 25 patients were studied more than 6 months (range, 6-96 months) after surgery. Angiograms of saphenous vein grafts (n = 11) or mammary artery grafts (n = 14) were obtained in basal conditions, after intravenous infusion of 0.4 mg methylergometrine, and after intragraft infusion of 1 mg isosorbide dinitrate. Computerized quantitative angiography was used to assess the changes in luminal diameter of the bypass graft and of the grafted coronary artery (n = 11). Methylergometrine reduced the diameter of saphenous vein grafts by 6.9 +/- 7.4%, from 3.26 +/- 0.71 to 3.05 +/- 0.76 mm (p < 0.01), and that of grafted coronary arteries by 9.3 +/- 7.2% (NS compared with saphenous vein grafts), from 2.08 +/- 0.49 to 1.89 +/- 0.49 mm (p < 0.005). The diameter of internal mammary artery grafts did not change significantly, from 3.27 +/- 0.42 to 3.25 +/- 0.44 mm (-0.3 +/- 5.1%, p < 0.02 compared with saphenous vein grafts and p < 0.002 compared with coronary arteries). After isosorbide dinitrate, the diameter of both grafted coronary arteries and mammary artery grafts increased significantly (respectively to 2.46 +/- 0.62 mm and 3.44 +/- 0.43 mm), the vasodilatation being greater (p < 0.002) in coronary arteries (+17.8 +/- 9.8% in proportion to basal diameter, p < 0.001) than in mammary grafts (+5.5 +/- 3.3%, p < 0.001). The diameter of saphenous vein grafts returned to control values (3.28 +/- 0.70 mm, NS compared with basal); the changes in luminal diameter after nitrates (+0.7 +/- 3.1%, NS) were significantly smaller than for mammary artery grafts (p < 0.01) and for grafted coronary arteries (p < 0.001).
Conclusions: Unlike internal mammary artery grafts, saphenous vein grafts constrict in response to methylergometrine and do not dilate in response to nitrates. These differences in vasomotor response could reflect heterogeneity in the sensitivity of vascular smooth muscle to these agents or differences in the basal level of vasomotor tone.
Similar articles
-
Flow-induced vasomotor response to tachycardia of the human internal mammary artery and saphenous vein grafts late following bypass surgery.Circulation. 1991 Nov;84(5 Suppl):III268-74. Circulation. 1991. PMID: 1934419
-
Flow capacity of internal mammary artery grafts: early restriction and later improvement assessed by Doppler guide wire. Comparison with saphenous vein grafts.J Am Coll Cardiol. 1995 Mar 1;25(3):640-7. doi: 10.1016/0735-1097(94)00448-Y. J Am Coll Cardiol. 1995. PMID: 7860908
-
Differences in vasoreactivity between gastroepiploic artery grafts late after bypass surgery and grafted coronary arteries.Circulation. 1994 Nov;90(5 Pt 2):II155-9. Circulation. 1994. PMID: 7955245 Clinical Trial.
-
Radial artery bypass grafts have an increased occurrence of angiographically severe stenosis and occlusion compared with left internal mammary arteries and saphenous vein grafts.Circulation. 2004 May 4;109(17):2086-91. doi: 10.1161/01.CIR.0000127570.20508.5C. Circulation. 2004. PMID: 15123539 Review.
-
Morphologic observations in biologic conduits between aorta and coronary artery.Cardiovasc Clin. 1977;8(2):11-40. Cardiovasc Clin. 1977. PMID: 332366 Review.
Cited by
-
Non-invasive Ischaemia Testing in Patients With Prior Coronary Artery Bypass Graft Surgery: Technical Challenges, Limitations, and Future Directions.Front Cardiovasc Med. 2021 Dec 23;8:795195. doi: 10.3389/fcvm.2021.795195. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 35004905 Free PMC article. Review.
-
Ventricular Fibrillation Due to Aortocoronary Vein Graft Spasm During Angiography: Case Report and Literature Review.JACC Case Rep. 2021 Mar 17;3(3):388-391. doi: 10.1016/j.jaccas.2020.12.044. eCollection 2021 Mar. JACC Case Rep. 2021. PMID: 34317543 Free PMC article.
-
How to standardize vasomotor tone in serial studies based on quantitation of coronary dimensions?Int J Card Imaging. 1998 Dec;14(6):357-72. doi: 10.1023/a:1006076409185. Int J Card Imaging. 1998. PMID: 10453390 Review.
-
Methylergometrine-induced myocardial ischemia in a previously asymptomatic premenopausal woman.Cardiovasc Drugs Ther. 1995 Aug;9(4):631-2. doi: 10.1007/BF00878096. Cardiovasc Drugs Ther. 1995. PMID: 8547214 No abstract available.
-
Pharmacological assessment of composite arterial conduits using angiography early in the postoperative period.Jpn J Thorac Cardiovasc Surg. 2004 Jun;52(6):279-85. doi: 10.1007/s11748-004-0043-x. Jpn J Thorac Cardiovasc Surg. 2004. PMID: 15242080
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous