Generalized approach to inverse problems in tomography: image reconstruction for spatially variant systems using natural pixels
- PMID: 1424686
Generalized approach to inverse problems in tomography: image reconstruction for spatially variant systems using natural pixels
Abstract
A major limitation in tomographic inverse problems is inadequate computation speed, which frequently impedes the application of engineering ideas and principles in medical science more than in the physical and engineering sciences. Medical problems are computationally taxing because a minimum description of the system often involves 5 dimensions (3 space, 1 energy, 1 time), with the range of each space coordinate requiring up to 512 samples. The computational tasks for this problem can be simply expressed by posing the problem as one in which the tomograph system response function is spatially invariant, and the noise is additive and Gaussian. Under these assumptions, a number of reconstruction methods have been implemented with generally satisfactory results for general medical imaging purposes. However, if the system response function of the tomograph is assumed more realistically to be spatially variant and the noise to be Poisson, the computational problem becomes much more difficult. Some of the algorithms being studied to compensate for position-dependent resolution and statistical fluctuations in the data acquisition process, when expressed in canonical form, are not practical for clinical applications because the number of computations necessary exceeds the capabilities of high-performance computer systems currently available. Reconstruction methods based on natural pixels, specifically orthonormal natural pixels, preserve symmetries in the data acquisition process. Fast implementations of orthonormal natural pixel algorithms can achieve orders of magnitude speedup relative to general implementations. Thus, specialized thought in algorithm development can lead to more significant increases in performance than can be achieved through hardware improvements alone.
Similar articles
-
Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels.Phys Med Biol. 2006 Jun 21;51(12):3105-25. doi: 10.1088/0031-9155/51/12/008. Epub 2006 May 31. Phys Med Biol. 2006. PMID: 16757866
-
Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.Phys Med Biol. 2009 Feb 7;54(3):715-29. doi: 10.1088/0031-9155/54/3/016. Epub 2009 Jan 9. Phys Med Biol. 2009. PMID: 19131666
-
Enhancing the performance of model-based elastography by incorporating additional a priori information in the modulus image reconstruction process.Phys Med Biol. 2006 Jan 7;51(1):95-112. doi: 10.1088/0031-9155/51/1/007. Epub 2005 Dec 15. Phys Med Biol. 2006. PMID: 16357433
-
A fast image reconstruction algorithm based on penalized-likelihood estimate.Med Eng Phys. 2005 Oct;27(8):679-86. doi: 10.1016/j.medengphy.2005.02.004. Med Eng Phys. 2005. PMID: 16139765
-
Advances in computers and image processing with applications in nuclear medicine.Q J Nucl Med. 2002 Mar;46(1):62-9. Q J Nucl Med. 2002. PMID: 12072846 Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources