Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992;65(5):438-44.
doi: 10.1007/BF00243511.

Assessment of human knee extensor muscles stress from in vivo physiological cross-sectional area and strength measurements

Affiliations

Assessment of human knee extensor muscles stress from in vivo physiological cross-sectional area and strength measurements

M V Narici et al. Eur J Appl Physiol Occup Physiol. 1992.

Abstract

The physiological cross-sectional areas (CSAp) of the vastus lateralis (VL), vastus intermedius (VI), vastus medialis (VM) and rectus femoris (RF) were obtained, in vivo, from the reconstructed muscle volumes, angles of pennation and distance between tendons of six healthy male volunteers by nuclear magnetic resonance imaging (MRI). In all subjects, the isometric maximum voluntary contraction strength (MVC) was measured at the optimum angle at which peak force occurred. The MVC developed at the ankle was 746.0 (SD 141.8) N and its tendon component (Ft), given by a mechanical advantage of 0.117 (SD 0.010), was 6.367 (SD 1.113) kN. To calculate the force acting along the fibres (Ff) of each muscle, Ft was divided by the cosine of the angle of pennation and multiplied for (CSAp.sigma CSAp-1), where sigma CSAp was the sum of CSAp of the four muscles. The resulting Ff values of VL, VI, VM and RF were: 1.452 (SD 0.531) kN, 1.997 (SD 0.187) kN, 1.914 (SD 0.827) kN, and 1.601 (SD 0.306) kN, respectively. The stress of each muscle was obtained by dividing these forces for the respective CSAp which was: 6.24 x 10(-3) (SD 2.54 x 10(-3)) m2 for VL, 8.35 x 10(-3) (SD 1.17 x 10(-3)) m2 for VI, 6.80 x 10(-3) (SD 2.66 x 10(-3)) m2 for VM and 6.62 x 10(-3) (SD 1.21 x 10(-3)) m2 for RF. The mean value of stress of VL, VI, VM and RF was 250 (SD 19) kN m-2; this value is in good agreement with data on animal muscle and those on human parallel-fibred muscle.

PubMed Disclaimer

References

    1. Physiol Rev. 1972 Jan;52(1):129-97 - PubMed
    1. Eur J Appl Physiol Occup Physiol. 1992;64(1):68-72 - PubMed
    1. Clin Physiol. 1984 Feb;4(1):23-32 - PubMed
    1. Eur J Appl Physiol Occup Physiol. 1989;59(4):310-9 - PubMed
    1. Eur J Appl Physiol Occup Physiol. 1988;57(1):39-44 - PubMed