Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1992 Aug-Sep;38(3):267-81.
doi: 10.1016/0166-0934(92)90072-l.

Serological detection of HBeAg and anti-HBe using automated microparticle enzyme immunoassays

Affiliations
Comparative Study

Serological detection of HBeAg and anti-HBe using automated microparticle enzyme immunoassays

D Robbins et al. J Virol Methods. 1992 Aug-Sep.

Abstract

Fully automated microparticle enzyme immunoassays (EIA) were developed for the detection of HBeAg (IMx HBe) and antibodies against HBeAg (IMx anti-HBe), respectively. Specimens from blood donors, diagnostic and hospital patients and individuals with a variety of infectious and immune diseases were tested both in house and at four clinical sites. The overall agreement between IMx HBe and Abbott HBe RIA/EIA was 99.7% (2985 of 2994) and between IMx anti-HBe and anti-HBe RIA/EIA was 95.8% (2330 of 2432). Almost all anti-HBe discordant specimens (94.1%, 96 of 102) were reactive by IMx anti-HBe but negative by anti-HBe RIA/EIA. off anti-HBe discordant specimens were also reactive for anti-HBc. The IMx anti-HBe assay was 2- to 4-fold more sensitive than the current RIA as determined by serial dilution of anti-HBe reactive specimens. The ability of these IMx assays to detect HBeAg and anti-HBe in 199 HBsAg reactive specimens was also evaluated. 43.7% (87 of 199) and 66.3% (132 of 199) specimens were reactive for HBeAg and anti-HBe by IMx, respectively. Only one specimen was negative for both IMx assays compared to 14 (7.0%) non-reactive for both HBe and anti-HBe RIA. There were 24 specimens (12.1%) positive for both HBeAg and anti-HBe by IMx compared to 1 (0.5%) positive by the corresponding RIAs. This increased detectability of anti-HBe in HBsAg carriers using IMx anti-HBe may result from increased sensitivity for 'free' anti-HBe and/or increased ability to detect anti-HBe in immune complex. IMx anti-HBe also detected more reactives among volunteer blood donor specimens reactive for anti-HBc but negative for HBsAg (55.5%, 86 of 155), compared to RIA (38.7%, 60 of 155). IMx anti-HBe may be useful in confirming prior exposure to HBV in blood screened positive by Corzyme.

PubMed Disclaimer

Similar articles

Publication types

Substances

LinkOut - more resources