Non-specific immunoglobulin interactions may lead to false-positive results in assays for human anti-mouse monoclonal antibodies (HAMA)
- PMID: 1430244
- DOI: 10.1080/15321819208021232
Non-specific immunoglobulin interactions may lead to false-positive results in assays for human anti-mouse monoclonal antibodies (HAMA)
Abstract
This abstract demonstrates that non-specific immunoglobulin interactions, of the F(ab')2 region and Fc piece of human IgG may lead to false-positive results in patients being monitored for naturally occurring (pre-existing) or induced human anti-mouse monoclonal Ig antibodies (HAMA). Patient sera tested before administration of murine monoclonal antibodies for immunoscintography or immunotherapy showed 'positive' results when screened by specific ELISA for the presence of pre-existing antibodies to murine immunoglobulin. However, only serum from a patient which had previously received murine monoclonal antibody for immunotherapy, was it possible to show specificity by competitive inhibition. Thus, the use of competitive inhibition by specific antigen (mouse Ig isotype/subtype), sera positive for HAMA or pre-existing HAMA can be distinguished from false-positive reactions.
Similar articles
-
Development of human anti-murine antibody (HAMA) response in patients.Immunol Cell Biol. 1990 Dec;68 ( Pt 6):367-76. doi: 10.1038/icb.1990.50. Immunol Cell Biol. 1990. PMID: 1711007
-
Human/mouse chimeric antibodies show low reactivity with human anti-murine antibodies (HAMA).Br J Cancer. 1992 Feb;65(2):197-200. doi: 10.1038/bjc.1992.41. Br J Cancer. 1992. PMID: 1739617 Free PMC article.
-
Human antibody response to the intravenous and intraperitoneal administration of the F(ab')2 fragment of the OC125 murine monoclonal antibody.J Immunother (1991). 1992 Jan;11(1):56-66. doi: 10.1097/00002371-199201000-00007. J Immunother (1991). 1992. PMID: 1734949
-
[Production of human antimurine antibody after in vivo use of radioisotope labelled murine antibodies].Ugeskr Laeger. 1991 Sep 30;153(40):2813-5. Ugeskr Laeger. 1991. PMID: 1926613 Review. Danish.
-
Human anti-mouse antibodies.Arch Pathol Lab Med. 2000 Jun;124(6):921-3. doi: 10.5858/2000-124-0921-HAMA. Arch Pathol Lab Med. 2000. PMID: 10835540 Review.
Cited by
-
Monitoring serum HER2 levels in breast cancer patients.Springerplus. 2015 May 22;4:237. doi: 10.1186/s40064-015-1015-6. eCollection 2015. Springerplus. 2015. PMID: 26069876 Free PMC article.
-
Interference-Free HER2 ECD as a Serum Biomarker in Breast Cancer.J Mol Biomark Diagn. 2014 Nov 14;4(3):151. doi: 10.4172/2155-9929.1000151. J Mol Biomark Diagn. 2014. PMID: 25089226 Free PMC article.