Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Nov 15;89(22):11069-73.
doi: 10.1073/pnas.89.22.11069.

Dynamic mapping of the human visual cortex by high-speed magnetic resonance imaging

Affiliations

Dynamic mapping of the human visual cortex by high-speed magnetic resonance imaging

A M Blamire et al. Proc Natl Acad Sci U S A. .

Abstract

We report the use of high-speed magnetic resonance imaging to follow the changes in image intensity in the human visual cortex during stimulation by a flashing checkerboard stimulus. Measurements were made in a 2.1-T, 1-m-diameter magnet, part of a Bruker Biospec spectrometer that we had programmed to do echo-planar imaging. A 15-cm-diameter surface coil was used to transmit and receive signals. Images were acquired during periods of stimulation from 2 s to 180 s. Images were acquired in 65.5 ms in a 10-mm slice with in-plane voxel size of 6 x 3 mm. Repetition time (TR) was generally 2 s, although for the long flashing periods, TR = 8 s was used. Voxels were located onto an inversion recovery image taken with 2 x 2 mm in-plane resolution. Image intensity increased after onset of the stimulus. The mean change in signal relative to the prestimulation level (delta S/S) was 9.7% (SD = 2.8%, n = 20) with an echo time of 70 ms. Irrespective of the period of stimulation, the increase in magnetic resonance signal intensity was delayed relative to the stimulus. The mean delay measured from the start of stimulation for each protocol was as follows: 2-s stimulation, delay = 3.5 s (SD = 0.5 s, n = 10) (the delay exceeds stimulus duration); 20- to 24-s stimulation, delay = 5 s (SD = 2 s, n = 20).

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Appl Physiol. 1954 Jun;6(12):731-44 - PubMed
    1. Nature. 1986 Nov 27-Dec 3;324(6095):361-4 - PubMed
    1. Proc Natl Acad Sci U S A. 1992 Jul 1;89(13):5951-5 - PubMed
    1. Proc Natl Acad Sci U S A. 1990 Aug;87(16):6082-6 - PubMed
    1. Magn Reson Med. 1990 Apr;14(1):68-78 - PubMed

Publication types

LinkOut - more resources