Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Sep;58(9):2737-43.
doi: 10.1128/aem.58.9.2737-2743.1992.

Hydrodynamic effects on microcapillary motility and chemotaxis assays of Methylosinus trichosporium OB3b

Affiliations

Hydrodynamic effects on microcapillary motility and chemotaxis assays of Methylosinus trichosporium OB3b

D R Shonnard et al. Appl Environ Microbiol. 1992 Sep.

Abstract

A study of the random motility and chemotaxis of Methylosinus trichosporium OB3b was conducted by using Palleroni-chamber microcapillary assay procedures. Under the growth conditions employed, this methanotroph was observed qualitatively with a microscope to be either slightly motile or essentially nonmotile. However, the cells did not not respond in the microcapillary assays in the manner expected for nonmotile Brownian particles. As a consequence, several hydrodynamic effects on these Palleroni microcapillary assays were uncovered. In the random-motility microcapillary assay, nondiffusive cell accumulations occurred that were strongly dependent upon cell concentration. An apparent minimal random-motility coefficient (mu) for this bacterial cell of 1.0 x 10(-7) cm2/s was estimated from microcapillary assays. A simple alternative spectrophotometric assay, based upon gravitational settling, was developed and shown to be an improvement over the Palleroni microcapillary motility assay for M. trichosporium OB3b in that it yielded a more-accurate threefold-lower random-motility coefficient. In addition, it provided a calculation of the gravitational-settling velocity. In the chemotaxis microcapillary assay, the apparent chemotactic responses were strongest for the highest test-chemical concentrations in the microcapillaries, were correlated with microcapillary fluid density, and were strongly dependent upon the microcapillary volume. A simple method to establish the maximal concentration of a chemical that can be tested and to quantify any contributions of abiotic convection is described. Investigators should be aware of the potential problems due to density-driven convection when using these commonly employed microcapillary assays for studying cells which have low motilities.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Gen Microbiol. 1977 Feb;98(2):329-37 - PubMed
    1. Appl Environ Microbiol. 1976 Nov;32(5):729-30 - PubMed
    1. Appl Environ Microbiol. 1991 Jan;57(1):228-35 - PubMed
    1. Appl Environ Microbiol. 1990 May;56(5):1501-3 - PubMed
    1. Appl Environ Microbiol. 1989 Dec;55(12):3155-61 - PubMed

Publication types

MeSH terms