Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1976 Jan;116(1):41-51.

Kinetics of the antibody response to type III pneumococcal polysaccharide (SSS-III). I. Use of 125I-labeled SSS-III to study serum antibody levels, as well as the distribution and excretion of antigen after immunization

  • PMID: 1445

Kinetics of the antibody response to type III pneumococcal polysaccharide (SSS-III). I. Use of 125I-labeled SSS-III to study serum antibody levels, as well as the distribution and excretion of antigen after immunization

J M Jones et al. J Immunol. 1976 Jan.

Abstract

A simple method was described for the preparation of 125I-labeled type III neumococcal polysaccharide (SSS-III) with a high specific radioactivity which retained the physical and immunologic properties of native SSS-III. SSS-III was used to study the serum and tissue levels of antigen, as well as its excretion, after i.p. injection. When an optimally immunogenic dose (0.5 mug) of antigen was given, greater than 90% of the injected antigen was excreted during the first 3 days after injection; however, after day 3, the SSS-III which remained in each mouse was firmly bound to various tissues, and less than 5 ng SSS-III was released into the circulation daily. SSS-III was also used in a Farr test to measure serum antibody levels; the kinetics for the appearance of PFC/spleen and serum antibody levels were measured at 24-hr intervals after immunization with 0.5 mug of antigen. Maximum PFC/spleen were observed on day 4 after immunization whereas the peak serum antibody level was seen on day 5. The decay of serum antibody level from its maximum value was much slower than that of the PFC/spleen. The data describing the distribution of SSS-III in vivo and the measurement of serum antibody levels indicated that treadmill neutralization was not a factor in determining the serum antibody levels after immunization with an optimally immunogenic dose of SSS-III.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources