Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Oct;99(4):841-6.
doi: 10.1097/00000542-200310000-00015.

Total oxygen uptake with two maximal breathing techniques and the tidal volume breathing technique: a physiologic study of preoxygenation

Affiliations

Total oxygen uptake with two maximal breathing techniques and the tidal volume breathing technique: a physiologic study of preoxygenation

Jaideep J Pandit et al. Anesthesiology. 2003 Oct.

Abstract

Background: Three common methods for preoxygenation are 3 min of tidal breathing, four deep breaths taken within 30 s (4DB), and eight deep breaths taken within 60 s (8DB). This report compares these three techniques in healthy volunteers.

Methods: Five healthy subjects breathed through a mouthpiece and wore a nose clip; oxygen was delivered at 180 l/min via a low-resistance T-piece. Each subject repeated each of the three oxygenation techniques four times. The end-tidal fraction of oxygen was measured, and the oxygen uptake at the mouth was measured breath by breath. The additional difference between oxygen uptake at the mouth during the period of breathing oxygen (as compared with that during air breathing) was taken to represent the total oxygen sequestrated into body stores.

Results: The mean +/- SD maximum end-tidal fraction of oxygen after the 4DB method was 0.83 +/- 0.09, which was significantly less than either after the 3-min method (0.92 +/- 0.01; P < 0.04) or after the 8DB method (0.91 +/- 0.04; P < 0.03). The mean additional oxygen taken up during oxygenation with the 4DB method was 1.67 +/- 0.45 l, which was significantly lower than with the 3-min method (2.23 +/- 0.85 l; P < 0.04) or with the 8DB method (2.53 +/- 0.74 l; P < 0.01). There were no significant differences for these variables between the 3-min and 8DB methods.

Conclusions: For the physiologic measurements that were made, both the 3-min and the 8DB method are superior to the 4DB method. The 3-min and 8DB methods seem to be equally effective.

PubMed Disclaimer

Comment in

  • Pre-oxygenation using a mouthpiece.
    Tosh W, Mendonca C. Tosh W, et al. Anaesthesia. 2016 Jul;71(7):855-6. doi: 10.1111/anae.13532. Anaesthesia. 2016. PMID: 27291610 No abstract available.

Publication types

LinkOut - more resources