Continuous glucose monitoring with glucose sensors: calibration and assessment criteria
- PMID: 14511412
- DOI: 10.1089/152091503322250596
Continuous glucose monitoring with glucose sensors: calibration and assessment criteria
Abstract
Continuous glucose monitoring (CM) by means of minimally invasive or noninvasive glucose sensors can help to further optimize metabolic control in patients with diabetes without need for frequent capillary blood glucose measurements. Most glucose sensors measure glucose concentration in the interstitial fluid (ISF). Because of the varying conditions in this compartment, a general in vitro calibration ( = factory calibration) by the manufacturer appears not to be possible. Therefore, calibration of the sensor signal must be performed by the patient himself repeatedly. The calibration procedure can be performed by means of conventional capillary blood glucose measurements in order to transform the sensor signals obtained from the specific compartment (e.g., ISF) into "blood" glucose values. A number of aspects can influence the validity of this procedure. The relationship between changes in blood glucose and in ISF glucose, in both time and concentration dimensions, is not well understood, especially during dynamic changes. The physical lag time, which critically depends on the glucose sensor technology used, can also introduce a systematic calibration error. After the first calibration, usually performed some hours after the application of a given glucose sensor, recalibration at certain intervals is necessary. Therefore, patients should critically assess the values displayed by a CM system. In the case of implausible glucose values they should verify the results by means of a conventional capillary glucose measurement. Up to now there is no consensus on assessment criteria to be used for evaluation of CM system performance and calibration quality. Existing methods of displaying CM values against corresponding reference values, including linear regression analysis and error grid analysis, as well as numeric criteria such as System Error, Predicted Error Sum of Squares (in %), and Mean Absolute Deviation are not generally applicable to CM. It appears as if they do not allow sufficient description of data obtained with CM systems. There is a pressing need to develop novel adequate assessment criteria enabling a better characterization of CM system performance. If these were used uniformly by all manufacturers and scientists assessing CM systems, this would allow a fair comparison of the performance of different systems.
Similar articles
-
Continuous glucose monitoring in subcutaneous tissue using factory-calibrated sensors: a pilot study.Diabetes Technol Ther. 2010 Aug;12(8):591-7. doi: 10.1089/dia.2010.0051. Diabetes Technol Ther. 2010. PMID: 20615099
-
Continuous glucose monitoring: an overview of today's technologies and their clinical applications.Int J Clin Pract Suppl. 2002 Jul;(129):75-9. Int J Clin Pract Suppl. 2002. PMID: 12166611 Review.
-
Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles.Diabetes Technol Ther. 2005 Feb;7(1):131-41. doi: 10.1089/dia.2005.7.131. Diabetes Technol Ther. 2005. PMID: 15738711
-
Hypoglycemia warning signal and glucose sensors: requirements and concepts.Diabetes Technol Ther. 2003;5(4):563-71. doi: 10.1089/152091503322250587. Diabetes Technol Ther. 2003. PMID: 14511411 Review.
-
The SCGM1 System: subcutaneous continuous glucose monitoring based on microdialysis technique.Diabetes Technol Ther. 2003;5(4):599-608. doi: 10.1089/152091503322250613. Diabetes Technol Ther. 2003. PMID: 14511414
Cited by
-
Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.J Diabetes Sci Technol. 2017 Sep;11(5):1028-1035. doi: 10.1177/1932296817698499. Epub 2017 Mar 14. J Diabetes Sci Technol. 2017. PMID: 28290224 Free PMC article. Review.
-
An automated discontinuous venous blood sampling system for ex vivo glucose determination in humans.J Diabetes Sci Technol. 2009 Jan;3(1):110-6. doi: 10.1177/193229680900300112. J Diabetes Sci Technol. 2009. PMID: 20046655 Free PMC article. Clinical Trial.
-
Numerical simulation of the effect of rate of change of glucose on measurement error of continuous glucose monitors.J Diabetes Sci Technol. 2007 Sep;1(5):685-94. doi: 10.1177/193229680700100512. J Diabetes Sci Technol. 2007. PMID: 19885136 Free PMC article.
-
Accuracy of a continuous glucose monitoring system applied before, during, and after an intense leg-squat session with low- and high-carbohydrate availability in young adults without diabetes.Eur J Appl Physiol. 2024 Dec;124(12):3557-3569. doi: 10.1007/s00421-024-05557-5. Epub 2024 Jul 22. Eur J Appl Physiol. 2024. PMID: 39037631 Free PMC article.
-
Clinical need for continuous glucose monitoring in the hospital.J Diabetes Sci Technol. 2009 Nov 1;3(6):1309-18. doi: 10.1177/193229680900300611. J Diabetes Sci Technol. 2009. PMID: 20144385 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical