Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Oct 1;67(1):112-20.
doi: 10.1002/jbm.a.10044.

Histomorphometric and microhardness assessments of sheep cortical bone surrounding titanium implants with different surface treatments

Affiliations

Histomorphometric and microhardness assessments of sheep cortical bone surrounding titanium implants with different surface treatments

G Giavaresi et al. J Biomed Mater Res A. .

Abstract

Several factors influence the healing process and the long-term mechanical stability of cementless fixed implants, such as bone remodeling and mineralization processes. Histomorphometric and bone hardness measurements were taken in implants inserted in sheep femoral cortical bone at different times to compare the in vivo osseointegration of titanium screws (diam.; 3.5 x 7 mm length) with the following surface treatments: machined (Ti-MA); acid-etched (Ti-HF); HA vacuum plasma spray (Ti-HA); and Ca-P anodization followed by a hydrothermal treatment (Ti-AM/HA). Ti-MA and Ti-AM/HA implants presented the lowest (Ra = 0.20 +/- 0.01 microm) and highest (Ra = 1.97 +/- 0.64 microm) significant (p < 0.0005) roughness value, respectively. Bone-to-implant contact of Ti-HF was lower than that of the other surface treatments at both experimental times (8 weeks: -20%, ns; 12 weeks: -30%, p < 0.01). Significant differences in MAR (mineral apposition rate) were also found between the different experimental times for Ti-MA (115%, p < 0.01) and Ti-HF (57%, p < 0.01), demonstrating that bone growth had slowed inside the screw threads of Ti-HA and Ti-AM/HA after 12 weeks. No bone microhardness changes in preexisting host bone were found, while Ti-MA showed the lowest value for the inner thread area at 8 weeks (HV(200 microm)= 49.8 +/- 3.8 HV). These findings confirm that osseointegration may be accelerated by adequate surface roughness and bioactive ceramic coating such as Ca-P anodization followed by a hydrothermal treatment, which enhance bone interlocking and mineralization.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources