Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Oct 5;795(2):371-6.
doi: 10.1016/s1570-0232(03)00562-2.

Simultaneous determination of 3'-azido-2',3'-dideoxyuridine and novel prodrugs in rat plasma by liquid chromatography

Affiliations

Simultaneous determination of 3'-azido-2',3'-dideoxyuridine and novel prodrugs in rat plasma by liquid chromatography

Linghui Kong et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

3'-Azido-2',3'-dideoxyuridine (AZDU) is a nucleoside analog structurally similar to zidovudine (AZT) with proven activity against human immunodeficiency virus (HIV). The purpose of this study was to develop and validate a high-performance liquid chromatographic (HPLC) method to quantitatively determine AZDU and its novel prodrugs in rat plasma simultaneously. A reversed-phase gradient elution HPLC method was developed to quantitate AZDU and its prodrugs, N3-pivaloyloxymethyl-3'-azido-2',3'-dideoxyuridine (I), 5'-pivaloyloxymethyl-3'-azido-2',3'-dideoxyuridine (II), 5'-O-valinyl-3'-azido-2',3'-dideoxyuridine hydrochloride (III) and 5'-O-phenylalanyl-3'-azido-2',3'-dideoxyuridine hydrochloride (IV), in rat plasma. AZDU and its prodrugs were analyzed using an octadecyl silane column with a mobile phase consisting of 0.04 microM sodium acetate buffer, pH 5.0, and acetonitrile, running in a segmented gradient manner at a flow rate of 2 ml/min. Acetonitrile was increased from 10 to 50% during the first 8 min by 5% per min, followed by 10% per min until it reached 90% acetonitrile. 3'-Azido-2',3'-dideoxy-5-ethyluridine (CS-85) was used as an internal standard (25 microg/ml). Compounds were detected by UV absorption at 261 nm. Extraction recoveries for all compounds were greater than 80%. Retention times of AZDU, CS-85, prodrugs I, II, III and IV were 3.3, 5.2, 9.1, 8.8, 6.3 and 7.3 min, respectively. Calibration plots were linear over the range of 0.25-100 microg/ml for AZDU and prodrugs II, III, and IV and 0.5-100 microg/ml for prodrug I. The limit of quantitation was 0.25 microg/ml for prodrugs II, III and IV and 0.5 microg/ml for prodrug I. The intra- and inter-day variations were less than 10% and accuracies were greater than 90%. This method is rapid, sensitive and reproducible for the determination of AZDU and prodrugs in rat plasma.

PubMed Disclaimer

Similar articles

Publication types

MeSH terms

LinkOut - more resources