Detection of cytokine receptors by high-sensitivity immunofluorescence/flow cytometry
- PMID: 1452210
- DOI: 10.1016/S0171-2985(11)80652-2
Detection of cytokine receptors by high-sensitivity immunofluorescence/flow cytometry
Abstract
Cytokines have profound effects on cells, and act through receptors which need only be at low concentrations (around 100 copies per cell) to transmit activation signals. The detection of such low concentrations is possible using monoclonal antibodies and fluorescence/flow cytometry, but only by using specialized techniques. The best results so far have been obtained using biotinylated second antibody followed by phycoerythrin-streptavidin, and batches of these reagents have to be carefully selected. Analysis of the fluorescence is best done using 546 nm excitation from a mercury arc lamp, but 512 nm excitation from an argon-ion laser can also be used. With appropriate alignment, instruments with 488 nm fixed-wavelength lasers can give sensitivity almost as good as the 546 nm system. Working at high sensitivity, background levels also increase, particularly for B lymphocytes. Background staining can be reduced to acceptable levels by blocking the two major mechanisms for non-specific binding. Applications of these methods to the detection of cytokine receptors on normal and malignant cells are reviewed.
Similar articles
-
Increased immunofluorescence sensitivity using 532 nm laser excitation.Cytometry A. 2007 Feb;71(2):73-9. doi: 10.1002/cyto.a.20358. Cytometry A. 2007. PMID: 17200955
-
Flow cytometric measurement of fluorescence (Förster) resonance energy transfer from cyan fluorescent protein to yellow fluorescent protein using single-laser excitation at 458 nm.Cytometry A. 2003 May;53(1):39-54. doi: 10.1002/cyto.a.10037. Cytometry A. 2003. PMID: 12701131
-
Single laser three color immunofluorescence staining procedures based on energy transfer between phycoerythrin and cyanine 5.Cytometry. 1991;12(8):723-30. doi: 10.1002/cyto.990120806. Cytometry. 1991. PMID: 1794253
-
Immunofluorescence measurement in a flow cytometer using low-power helium-neon laser excitation.Cytometry. 1983 Nov;4(3):276-9. doi: 10.1002/cyto.990040314. Cytometry. 1983. PMID: 6363017
-
Assays for lymphokines, cytokines and their receptors.Curr Opin Immunol. 1991 Apr;3(2):247-51. doi: 10.1016/0952-7915(91)90060-e. Curr Opin Immunol. 1991. PMID: 2069752 Review.
Cited by
-
Expression of IL-2R, IL-4R, IL-6R on peripheral blood lymphocytes in systemic lupus erythematosus and correlation with disease activity: a prospective study.J Clin Pathol. 1996 Aug;49(8):660-3. doi: 10.1136/jcp.49.8.660. J Clin Pathol. 1996. PMID: 8881918 Free PMC article.
-
Lipid-peptide bioconjugation through pyridyl disulfide reaction chemistry and its application in cell targeting and drug delivery.J Nanobiotechnology. 2019 Jun 21;17(1):77. doi: 10.1186/s12951-019-0509-8. J Nanobiotechnology. 2019. PMID: 31226993 Free PMC article.
-
Reduced expression of the interleukin-2-receptor gamma chain on cord blood lymphocytes: relationship to functional immaturity of the neonatal immune response.Immunology. 1996 Jan;87(1):86-91. Immunology. 1996. PMID: 8666440 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources