[A comparison of corneal sensitivity between healthy cats and cats with corneal sequestra]
- PMID: 14526473
[A comparison of corneal sensitivity between healthy cats and cats with corneal sequestra]
Abstract
In order to establish reference values for corneal sensitivity in ophthalmologically healthy persians (n = 40) and domestic short hair cats (n = 60) a prospective study was conducted. Furthermore corneal sensitivity in 48 cats with a corneal sequestrum was measured. Corneal sensitivity was recorded with the help of the aesthesiometer according to Cochet and Bonnet in five different corneal locations (central, nasal, dorsal, temporal, and ventral). The sensitivity for the central corneal region was recorded as amounting to 3.58 +/- 0.56 cm in ophthalmologically healthy domestic short hair cats and to 2.97 +/- 0.58 cm in healthy persian cats. The sensitivity of the central corneal area of a cat with a corneal sequester only amounts to 2.03 +/- 0.53 cm. Between the diseased and the healthy eyes no statistical difference could be demonstrated for any of the measured corneal locations. The sensitivity of the peripheral corneal locations is significantly lower than that of the central corneal region in all three groups examined.