Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Oct 4;362(9390):1093-9.
doi: 10.1016/S0140-6736(03)14462-5.

Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS)

Affiliations
Clinical Trial

Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS)

Joachim Schofer et al. Lancet. .

Abstract

Background: Sirolimus-eluting stents have been developed to prevent restenosis in the treatment of coronary artery disease. We investigated the risk of restenosis with use of sirolimus-eluting stents compared with bare-metal stents to assess possible differences.

Methods: We enrolled 352 patients in whom one coronary artery required treatment, with diameter 2.5-3.0 mm and lesion length 15-32 mm. We randomly assigned patients sirolimus-eluting stents (n=175) or bare-metal stents (control, n=177). At 8 months we assessed differences in minimum lumen diameter and binary restenosis within the lesion (restenosis of > or =50% diameter, including 5 mm vessel segments proximal and distal to stented segment). Patients were also followed up for 9 months for major adverse cardiac events. Analysis was by intention to treat.

Findings: Stent implantation was successful in 100% of sirolimus-stent patients and 99.4% of controls. The mean diameter of treated coronary arteries was 2.55 mm (SD 0.37) and mean lesion length was 15.0 mm (6.0). Multiple stents were implanted in 170 (48%) patients. At 8 months, minimum lumen diameter was significantly higher with sirolimus-eluting stents than with control stents (2.22 vs 1.33 mm, p<0.0001). The rate of binary restenosis was significantly reduced with sirolimus-eluting stents compared with control stents (5.9 vs 42.3%, p=0.0001). Significantly fewer patients with sirolimus-eluting stents had major adverse cardiac events at 9 months than did controls (8.0 vs 22.6%, p=0.0002), due mainly to a lower need for target-lesion revascularisations (4.0 vs 20.9%, p<0.0001).

Interpretation: Sirolimus-eluting stents are better than bare-metal stents for treatment of single long atherosclerotic lesions in a coronary vessel smaller than 3 mm in diameter.