Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Oct;124(4):395-402.
doi: 10.1016/s0889-5406(03)00504-3.

Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations

Affiliations
Comparative Study

Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations

Vittorio Cacciafesta et al. Am J Orthod Dentofacial Orthop. 2003 Oct.

Abstract

This study measured and compared the level of frictional resistance generated between stainless steel self-ligating brackets (Damon SL II, SDS Ormco, Glendora, Calif), polycarbonate self-ligating brackets (Oyster, Gestenco International, Göthenburg, Sweden), and conventional stainless steel brackets (Victory Series, 3M Unitek, Monrovia, Calif), and 3 different orthodontic wire alloys: stainless steel (Stainless Steel, SDS Ormco), nickel-titanium (Ni-Ti, SDS Ormco), and beta-titanium (TMA, SDS Ormco). All brackets had a.022-in slot, whereas the orthodontic wire alloys were tested in 3 different sections:.016,.017 x.025, and.019 x 0.025 in. Each of the 27 bracket and archwire combinations was tested 10 times, and each test was performed with a new bracket-wire sample. Both static and kinetic friction were measured on a custom-designed apparatus. All data were statistically analyzed (Kruskal-Wallis and Mann Whitney U tests). Stainless steel self-ligating brackets generated significantly lower static and kinetic frictional forces than both conventional stainless steel and polycarbonate self-ligating brackets, which showed no significant differences between them. Beta-titanium archwires had higher frictional resistances than stainless steel and nickel-titanium archwires. No significant differences were found between stainless steel and nickel-titanium archwires. All brackets showed higher static and kinetic frictional forces as the wire size increased.

PubMed Disclaimer

Comment in

  • Kinetic friction.
    Smart FM. Smart FM. Am J Orthod Dentofacial Orthop. 2004 Feb;125(2):17A; author reply 17A. doi: 10.1016/j.ajodo.2003.11.013. Am J Orthod Dentofacial Orthop. 2004. PMID: 14989274 No abstract available.

Publication types

LinkOut - more resources