Effects of pupil diameter on light detection and temporal modulation
- PMID: 14574966
Effects of pupil diameter on light detection and temporal modulation
Abstract
Purpose: This study compared the effects of pupil variation on light detection and temporal modulation across the central visual field.
Methods: Light detection sensitivity (LDS) and low flickering frequency (6 Hz) temporal modulation sensitivity (TMS) of 20 young subjects were measured from the central visual field of the right eyes using an autumated perimeter (Medmont M600). The measurements were taken under 3 artificial pupils, i.e. 3 mm, 4.3 mm and 6 mm diameters. The sensitivities were grouped and averaged for different retinal eccentricities (3 degrees, 6 degrees, 10 degrees, and 15 degrees).
Results: TMS and LDS were reduced with increasing retinal eccentricities (P < 0.001) and decreasing pupil diameters (P < 0.001). TMS collected from all pupil diameters were significantly different from each other (P < 0.001). Similarly, LDS under 3 mm pupil was statistically different from those of 4.3 mm and 6 mm (P < 0.003). Comparison of the hills of vision showed that pupil variation resulted in significantly different slopes (P = 0.001). The slopes were also found to be significantly different between TMS and LDS (P = 0.012).
Conclusions: The data showed that dilated pupil resulted in significantly higher sensitivities than those of smaller pupil for both visual functions. The difference in the slopes of hills of vision also suggested that the variation in retinal illumination affected the visual responses differently at various retinal eccentricities for TMS and LDS.
Similar articles
-
Characteristics of the pupillary light reflex in the alert rhesus monkey.J Neurophysiol. 2003 Jun;89(6):3179-89. doi: 10.1152/jn.01131.2002. Epub 2003 Jan 15. J Neurophysiol. 2003. PMID: 12611973
-
[A new method to explore the modulation from the saccadic system on the pupillary light reflex system].Dongwuxue Yanjiu. 2010 Jun;31(3):287-91. doi: 10.3724/SP.J.1141.2010.03287. Dongwuxue Yanjiu. 2010. PMID: 20672417 Chinese.
-
Effect of Target Luminance on Optimum Pupil Diameter for Presbyopic Eyes.Optom Vis Sci. 2016 Nov;93(11):1409-1419. doi: 10.1097/OPX.0000000000000963. Optom Vis Sci. 2016. PMID: 27560851
-
[Pupil and melanopsin photoreception].Nippon Ganka Gakkai Zasshi. 2013 Mar;117(3):246-68; discussion 269. Nippon Ganka Gakkai Zasshi. 2013. PMID: 23631256 Review. Japanese.
-
Pupil assessment in optic nerve disorders.Eye (Lond). 2004 Nov;18(11):1175-81. doi: 10.1038/sj.eye.6701560. Eye (Lond). 2004. PMID: 15534603 Review.