Affinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c
- PMID: 1458570
Affinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c
Abstract
We describe an automated assay of glycohemoglobin performed with the Abbott Vision analyzer. The assay is based on batch affinity-extraction with 3-aminophenylboronic acid-derivatized agarose beads. Reagents are packaged in a disposable test pack. Whole-blood specimens are hemolyzed with saponin within a glass capillary tube inserted into the test pack. The sample is automatically diluted with, mixed with, and separated from the solid-phase reagent. Bichromatic absorbance readings are used to calculate the percentage of hemoglobin bound. Based on the linear correlation between affinity-measured glycohemoglobin and HPLC-measured hemoglobin A1c, the percentage of hemoglobin bound is converted to a "standardized %HbA1c" result by use of regression parameters stored during a calibration run. The combination of affinity methodology with standardization by reference to HPLC produces values directly comparable with those obtained by methods specific for HbA1c. The method produces 10 results within 15 min. The assay operates with CVs < 5%, and the results correlate highly with those by ion-exchange and affinity minicolumn methods, and by ion-exchange HPLC.
Comment in
-
Standardization, calibration, and the care of diabetic patients.Clin Chem. 1992 Dec;38(12):2363-4. Clin Chem. 1992. PMID: 1458568 No abstract available.
Similar articles
-
Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.Clin Chem. 1993 Oct;39(10):2090-7. Clin Chem. 1993. PMID: 7691440
-
Three assays for glycohemoglobin compared.Clin Chem. 1995 Feb;41(2):191-5. Clin Chem. 1995. PMID: 7874770
-
Multicenter evaluation of Tosoh glycohemoglobin analyzer.Clin Chem. 1999 Oct;45(10):1833-41. Clin Chem. 1999. PMID: 10508131 Clinical Trial.
-
[Standard material for measurement of hemoglobin A1c].Rinsho Byori. 2001 Dec;49(12):1199-204. Rinsho Byori. 2001. PMID: 11797388 Review. Japanese.
-
A review of the challenge in measuring hemoglobin A1c.J Diabetes Sci Technol. 2009 May 1;3(3):439-45. doi: 10.1177/193229680900300306. J Diabetes Sci Technol. 2009. PMID: 20144280 Free PMC article. Review.
Cited by
-
Artifactually low glycated haemoglobin in a patient with severe hypertriglyceridaemia.J Clin Pathol. 2003 May;56(5):394-5. doi: 10.1136/jcp.56.5.394. J Clin Pathol. 2003. PMID: 12719463 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical