Evaluation of capture ELISA for detection of antineutrophil cytoplasmic antibodies directed against proteinase 3 in Wegener's granulomatosis: first results from a multicentre study
- PMID: 14585921
- DOI: 10.1093/rheumatology/keh028
Evaluation of capture ELISA for detection of antineutrophil cytoplasmic antibodies directed against proteinase 3 in Wegener's granulomatosis: first results from a multicentre study
Abstract
Objective: To evaluate the performance characteristics of direct and capture ELISA for the detection of PR3-ANCA in Wegener's granulomatosis (WG) in international ANCA reference laboratories.
Methods: Serum samples were derived from patients with histological and clinical diagnosis of WG (n = 60), rheumatoid arthritis (RA) (n = 30) and healthy controls (n = 30). Each of them was tested for the presence of ANCA by indirect immunofluorescence technique (IFT), direct and capture ELISA in six international reference laboratories (Massachusetts General Hospital, Boston; Wieslab AB, Lund; University of Maastricht; University Hospital Groningen; Mayo Clinic, Rochester; Rheumaklinik Bad Bramstedt/University of Schleswig-Holstein Campus Lübeck). Each centre tested the sera according to their house protocols of IFT and ELISA. The diagnostic performance of each test was estimated by receiver operating characteristic curve analysis and sensitivity and specificity in detection of ANCA/PR3-ANCA were calculated for the respective methods.
Results: In patients histologically and clinically known as WG, the detection of ANCA by IFT varied between 52 and 83% among the participating centres. PR3-ANCA positivity with the different ELISAs ranged from 53 to 80% in direct ELISA and from 72 to 76% in capture ELISA. While most capture ELISAs successfully detected PR3-ANCA, there were significant differences between IFT and direct ELISA results between laboratories. ROC curve analysis demonstrated that in five of six laboratories the overall diagnostic performance of capture ELISA was superior to IFT and direct ELISA, respectively.
Conclusion: Capture ELISA is a highly sensitive assay for detection of PR3-ANCA in WG and should be used in conjunction with compatible clinical picture and histological evidence.
Similar articles
-
A critical evaluation of commercial immunoassays for antineutrophil cytoplasmic antibodies directed against proteinase 3 and myeloperoxidase in Wegener's granulomatosis and microscopic polyangiitis.Rheumatology (Oxford). 2002 Nov;41(11):1313-7. doi: 10.1093/rheumatology/41.11.1313. Rheumatology (Oxford). 2002. PMID: 12422006
-
Antineutrophil cytoplasmic antibody measurement: advantages and disadvantages of a capture PR3 ELISA and a direct PR3 ELISA.Pathology. 2007 Apr;39(2):258-63. doi: 10.1080/00313020701230641. Pathology. 2007. PMID: 17454758
-
Comparison of anti-PR3 capture and anti-PR3 direct ELISA for detection of antineutrophil cytoplasmic antibodies (ANCA) in long-term clinical follow-up of PR3-ANCA-associated vasculitis patients.Clin Nephrol. 2001 Oct;56(4):295-301. Clin Nephrol. 2001. PMID: 11680659
-
What do antineutrophil cytoplasmic antibodies (ANCA) tell us?Best Pract Res Clin Rheumatol. 2005 Apr;19(2):263-76. doi: 10.1016/j.berh.2004.10.003. Best Pract Res Clin Rheumatol. 2005. PMID: 15857795 Review.
-
Wegener's granulomatosis--autoimmunity to neutrophil proteinase 3.Arch Immunol Ther Exp (Warsz). 2003;51(3):157-67. Arch Immunol Ther Exp (Warsz). 2003. PMID: 12894870 Review.
Cited by
-
Epitope specificity determines pathogenicity and detectability in ANCA-associated vasculitis.J Clin Invest. 2013 Apr;123(4):1773-83. doi: 10.1172/JCI65292. Epub 2013 Mar 15. J Clin Invest. 2013. PMID: 23549081 Free PMC article.
-
Granulomatosis with polyangiitis in childhood.Curr Rheumatol Rep. 2012 Apr;14(2):107-115. doi: 10.1007/s11926-012-0238-6. Curr Rheumatol Rep. 2012. PMID: 22286604 Review.
-
Novel clinical and diagnostic aspects of antineutrophil cytoplasmic antibodies.J Immunol Res. 2014;2014:185416. doi: 10.1155/2014/185416. Epub 2014 Jun 5. J Immunol Res. 2014. PMID: 24995343 Free PMC article. Review.
-
[Paradigm shift in ANCA diagnostics : New international consensus recommendations].Z Rheumatol. 2017 Mar;76(2):143-148. doi: 10.1007/s00393-016-0240-x. Z Rheumatol. 2017. PMID: 28058500 Review. German.
-
Automated interpretation of ANCA patterns - a new approach in the serology of ANCA-associated vasculitis.Arthritis Res Ther. 2012 Dec 14;14(6):R271. doi: 10.1186/ar4119. Arthritis Res Ther. 2012. PMID: 23241527 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials