The multiload IUD--a U.S. researcher's evaluation of a European device
- PMID: 1458888
- DOI: 10.1016/0010-7824(92)90145-j
The multiload IUD--a U.S. researcher's evaluation of a European device
Abstract
This evaluative review focused on the performance and safety of the Dutch-made Multiload copper IUD, primarily the Multiload-375 (MLCu-375) model which has a longer life expectancy (5 or more years) than the Multiload-250 (MLCu-250) model, usually cited for a life expectancy for three years. This copper-medicated IUD differs from the copper-T IUDs in shape and insertion technique. The review shows that (a) the MLCu-375 IUD seems to be slightly less effective in preventing pregnancies than TCu-380A IUD. Its efficacy is comparable to that of the Nova-T by two to three years of use; (b) the MLCu-250 IUD is similarly effective to TCu-200 but may be slightly less effective than TCu-220C; (c) no consistent differences were detectable in expulsion rates or in removal rates for bleeding/pain between the Multiload IUDs and comparative Copper-T IUDs; (d) the Multiload IUDs may perform better in nulliparous women than the T-shaped devices; (e) no or a very low incidence of uterine perforation is associated with insertions of the Multiload IUD; (f) ectopic pregnancy risks are similarly low in Multiload IUD users as in Copper-T-380A users; and (g) pelvic inflammatory disease (PID) risks are similarly low in Multiload IUD users as in users of T-shaped copper IUDs.
Similar articles
-
Performances of copper T 380A and multiload copper 375/250 intrauterine contraceptive devices in a comparative clinical trial.Afr J Med Med Sci. 1995 Mar;24(1):59-65. Afr J Med Med Sci. 1995. PMID: 7495202 Clinical Trial.
-
Twelve-month comparative multicenter study of the TCu 380A and ML 250 intrauterine devices in Bangkok, Thailand.Contraception. 1998 Oct;58(4):201-6. doi: 10.1016/s0010-7824(98)00097-3. Contraception. 1998. PMID: 9865999 Clinical Trial.
-
The TCu-380A (AG), MLCu375, and Nova-T IUDs and the IUD daily releasing 20 micrograms levonorgestrel--four pillars of IUD contraception for the nineties and beyond?Contraception. 1993 Apr;47(4):325-47. doi: 10.1016/0010-7824(93)90031-2. Contraception. 1993. PMID: 8508663 Review.
-
A comparative clinical trial of the TCu 380A, Lippes Loop D and Multiload Cu 375 IUDs in Indonesia.Contraception. 1991 Aug;44(2):141-54. doi: 10.1016/0010-7824(91)90114-u. Contraception. 1991. PMID: 1893708 Clinical Trial.
-
An evaluation of the levonorgestrel-releasing IUD: its advantages and disadvantages when compared to the copper-releasing IUDs.Contraception. 1991 Dec;44(6):573-88. doi: 10.1016/0010-7824(91)90078-t. Contraception. 1991. PMID: 1773615 Review.
Cited by
-
Comparing Hemorrhages and Dysmenorrhea with Copper T380A and Multiload 375 Intrauterine Devices: A Randomized Clinical Trial.J Caring Sci. 2014 Sep 1;3(3):193-204. doi: 10.5681/jcs.2014.021. eCollection 2014 Sep. J Caring Sci. 2014. PMID: 25276763 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources