Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective dose
- PMID: 14596311
- DOI: 10.1118/1.1611291
Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective dose
Abstract
Conventional chest radiography is technically difficult because of wide variations in tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometric and equipment limitations inherent in mobile x-ray procedures and the severity of illness in the patients. Computed radiography (CR) offers a different approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. Because they are more efficient in absorbing lower-energy x-rays than rare-earth intensifying screens, this study evaluated changes in kVp for improving mobile chest CR. Three commercially available systems were tested, with the goal of implementing the findings clinically. Exposure conditions (kVp and grid use) were assessed with two acrylic-and-aluminum chest phantoms which simulated x-ray attenuation for average-sized and large-sized adult chests. These phantoms contained regions representing the lungs, heart and subdiaphragm to allow proper CR processing. Signal-to-noise ratio (SNR) measurements using different techniques were obtained for acrylic and aluminum disks (1.9 cm diameter) superimposed in the lung and heart regions of the phantoms, where the disk thicknesses (contrast) were determined from disk visibility. Effective doses to the phantoms were also measured for these techniques. The results indicated that using an 8:1, 33 lines/cm antiscatter grid improved the SNR by 60-300 % compared with nongrid images, depending on phantom and region; however, the dose to the phantom also increased by 400-600%. Lowering x-ray tube potential from 80 to 60 kVp improved the SNR by 30-40%, with a corresponding increase in phantom dose of 40-50%. Increasing the potential from 80 to 100 kVp reduced both the SNR and the phantom dose by approximately 10%. The most promising changes in technique for trial in clinical implementation include using an antiscatter grid, especially for large patients, and potentially increasing kVp.
Similar articles
-
Dose-image quality optimisation in digital chest radiography.Radiat Prot Dosimetry. 2005;114(1-3):269-72. doi: 10.1093/rpd/nch546. Radiat Prot Dosimetry. 2005. PMID: 15933120
-
Comparative study between mobile computed radiography and mobile flat-panel radiography for bedside chest radiography: impact of an antiscatter grid on the visibility of selected diagnostically relevant structures.Invest Radiol. 2014 Jan;49(1):1-6. doi: 10.1097/RLI.0b013e3182a56654. Invest Radiol. 2014. PMID: 24019019
-
High-ratio grid considerations in mobile chest radiography.Med Phys. 2012 Jun;39(6):3142-53. doi: 10.1118/1.4711751. Med Phys. 2012. PMID: 22755699
-
Stimulable phosphor plates in chest radiology.Eur Radiol. 1997;7 Suppl 3:S83-6. Eur Radiol. 1997. PMID: 9169106 Review.
-
Digital chest radiography at the University of Chicago: present status and future plans.J Digit Imaging. 1995 Feb;8(1 Suppl 1):11-4. doi: 10.1007/BF03168059. J Digit Imaging. 1995. PMID: 7734531 Review.
Cited by
-
Impact of mobile radiography services in nursing homes on the utilisation of diagnostic imaging procedures.BMC Health Serv Res. 2019 Jun 26;19(1):428. doi: 10.1186/s12913-019-4276-x. BMC Health Serv Res. 2019. PMID: 31242914 Free PMC article.
-
Dependence of radiographic sensitivity of CR imaging plate on X-ray tube voltage.Radiol Phys Technol. 2008 Jan;1(1):100-5. doi: 10.1007/s12194-007-0015-9. Epub 2007 Dec 11. Radiol Phys Technol. 2008. PMID: 20821170
-
Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment.J Digit Imaging. 2006 Dec;19(4):383-90. doi: 10.1007/s10278-006-0625-5. J Digit Imaging. 2006. PMID: 16741663 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources