Automatic registration of the prostate for computed-tomography-guided radiotherapy
- PMID: 14596313
- DOI: 10.1118/1.1608497
Automatic registration of the prostate for computed-tomography-guided radiotherapy
Abstract
The recent development of integrated computed tomography (CT)/linear accelerator (LINAC) combinations, where the CT scanner and the LINAC use the same patient couch, and of kilovoltage cone-beam CT systems attached to the LINAC gantry, means that suitable hardware is now available for CT-guided localization of the prostate. Clinical implementation is, however, currently impeded by the lack of robust and accurate software tools to compare the position of the prostate in the CT images used for the treatment plan with its position in the daily CT images. Manual registration of the planning CT images with the daily CT images can be slow and can introduce significant inter-user variations. We have developed an automatic registration technique that is not adversely influenced by changes in prostate shape, size or orientation, presence of rectal gas, or bladder filling. The cost function used in the registration is the mean absolute difference in CT numbers voxel-by-voxel between the daily CT image and the planning CT image for a volume extracted from the planning CT images using the original physician-drawn gross tumor volume contours. To enhance soft tissue contrast in the prostate region and to reduce the impact of rectal gas calcifications and bone on the registration, voxels with CT numbers that represent gas or bone are filtered out from the calculation. The results of the automatic registration agreed with the mean results of seven human observers, with standard deviations of 0.5 mm, 0.5 mm, and 1.0 mm in the left/right (RL), anterior/posterior (AP), and superior/inferior (SI) directions, respectively, for a patient that was relatively easy to localize. Agreement (one standard deviation) for a patient that was difficult to localize was 0.6 mm, 1.4 mm, and 1.9 mm in the RL, AP, and SI directions, respectively. These results are better than the interuser uncertainties reported for a manual alignment technique and are close to the reported intrauser uncertainties. The results are independent of the shape of contours in the original treatment plan, reducing the impact of interobserver variations in contouring the prostate. The algorithm is fast and reliable, allowing the entire CT localization process to take place in 5-9 minutes. In 120 CT image sets from seven patients, the failure rate was found to be less than 1%. The use of this algorithm will facilitate the clinical implementation of CT-guided localization of the prostate.
Similar articles
-
Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study.Int J Radiat Oncol Biol Phys. 2004 Jun 1;59(2):412-8. doi: 10.1016/j.ijrobp.2003.10.023. Int J Radiat Oncol Biol Phys. 2004. PMID: 15145157
-
An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer.Int J Radiat Oncol Biol Phys. 2005 May 1;62(1):154-63. doi: 10.1016/j.ijrobp.2004.09.045. Int J Radiat Oncol Biol Phys. 2005. PMID: 15850916
-
Automatic localization of the prostate for on-line or off-line image-guided radiotherapy.Int J Radiat Oncol Biol Phys. 2004 Oct 1;60(2):623-35. doi: 10.1016/j.ijrobp.2004.05.027. Int J Radiat Oncol Biol Phys. 2004. PMID: 15380600
-
[Image-guided radiotherapy by in-room CT-linear accelerator combination].Cancer Radiother. 2006 Sep;10(5):245-51. doi: 10.1016/j.canrad.2006.06.004. Epub 2006 Sep 7. Cancer Radiother. 2006. PMID: 16959518 Review. French.
-
[Application of PET-LINAC in Biology-guided Radiotherapy].Zhongguo Yi Liao Qi Xie Za Zhi. 2023 May 30;47(3):237-241. doi: 10.3969/j.issn.1671-7104.2023.03.001. Zhongguo Yi Liao Qi Xie Za Zhi. 2023. PMID: 37288620 Review. Chinese.
Cited by
-
A novel dose-based positioning method for CT image-guided proton therapy.Med Phys. 2013 May;40(5):051714. doi: 10.1118/1.4801910. Med Phys. 2013. PMID: 23635262 Free PMC article.
-
Automated registration of hip and spine for longitudinal QCT studies: integration with 3D densitometric and structural analysis.Bone. 2006 Feb;38(2):273-9. doi: 10.1016/j.bone.2005.08.014. Epub 2005 Sep 30. Bone. 2006. PMID: 16199215 Free PMC article.
-
Technological advances in radiation therapy for prostate cancer.Curr Urol Rep. 2010 May;11(3):172-9. doi: 10.1007/s11934-010-0102-z. Curr Urol Rep. 2010. PMID: 20425624 Review.
-
Differences between planned and delivered dose for head and neck cancer, and their consequences for normal tissue complication probability and treatment adaptation.Radiother Oncol. 2020 Jan;142:100-106. doi: 10.1016/j.radonc.2019.07.034. Epub 2019 Aug 17. Radiother Oncol. 2020. PMID: 31431381 Free PMC article.
-
Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.Clin Med Oncol. 2008;2:289-99. doi: 10.4137/cmo.s512. Epub 2008 Mar 28. Clin Med Oncol. 2008. PMID: 21892290 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical