Wrist arthrodesis using a Synthes wrist fusion plate
- PMID: 14599830
- DOI: 10.1016/s0266-7681(03)00146-3
Wrist arthrodesis using a Synthes wrist fusion plate
Abstract
Thirty-nine patients were retrospectively reviewed after a wrist arthrodesis using a Synthes wrist fusion plate and iliac crest bone graft. Information was obtained from review of patient files, a questionnaire to assess pain, function and work status, and clinical assessment of grip strength, forearm rotation and fingers motion. All wrist fusions united except that the index carpometacarpal joint failed to unite in one patient. Thirty-seven patients were satisfied with the procedure, noting a reduction in wrist pain after fusion, but all reported some limitation of function. The wrist fusion plate was removed in six patients and a further four patients experienced minor symptoms over the dorsal aspect of the middle finger metacarpal.