Capsulotomy diameter mark
- PMID: 14604703
- DOI: 10.1016/s0886-3350(03)00354-7
Capsulotomy diameter mark
Abstract
Recent improvements in intraocular lens (IOL) design and material delay posterior capsule opacification (PCO) after cataract surgery. However, studies have shown that without anterior capsule coverage of the IOL, PCO rates tend to increase. Surgeons have traditionally sized anterior capsulotomies without using a reference. The capsulotomy diameter mark is a convenient and inexpensive method to more consistently perform an anterior capsulorhexis that will allow anterior capsule overlap of the IOL optic.
Comment in
-
Capsulotomy diameter mark.J Cataract Refract Surg. 2004 Oct;30(10):2031-2. doi: 10.1016/j.jcrs.2004.08.013. J Cataract Refract Surg. 2004. PMID: 15474794 No abstract available.
Similar articles
-
Capsulotomy diameter mark.J Cataract Refract Surg. 2004 Oct;30(10):2031-2. doi: 10.1016/j.jcrs.2004.08.013. J Cataract Refract Surg. 2004. PMID: 15474794 No abstract available.
-
The effect of capsulorhexis size on development of posterior capsule opacification: small (4.5 to 5.0 mm) versus large (6.0 to 7.0 mm).Eur J Ophthalmol. 2003 Jul;13(6):541-5. doi: 10.1177/112067210301300606. Eur J Ophthalmol. 2003. PMID: 12948312 Clinical Trial.
-
Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up.J Cataract Refract Surg. 2001 Sep;27(9):1359-65. doi: 10.1016/s0886-3350(01)00892-6. J Cataract Refract Surg. 2001. PMID: 11566516
-
Intraocular lens optic capture.J Cataract Refract Surg. 2004 Jan;30(1):200-6. doi: 10.1016/j.jcrs.2003.11.035. J Cataract Refract Surg. 2004. PMID: 14967291 Review.
-
Techniques of anterior capsulotomy in cataract surgery.Indian J Ophthalmol. 2019 Apr;67(4):450-460. doi: 10.4103/ijo.IJO_1728_18. Indian J Ophthalmol. 2019. PMID: 30900573 Free PMC article. Review.
Cited by
-
Modified bandage-contact-lens used as a guide-marker for performing continuous-curvilinear-capsulorhexis by a first-year-post-graduate-ophthalmology-resident.Am J Ophthalmol Case Rep. 2020 Aug 26;20:100889. doi: 10.1016/j.ajoc.2020.100889. eCollection 2020 Dec. Am J Ophthalmol Case Rep. 2020. PMID: 32944672 Free PMC article.
-
A practical continuous curvilinear capsulorhexis self-training system.Indian J Ophthalmol. 2021 Oct;69(10):2678-2686. doi: 10.4103/ijo.IJO_210_21. Indian J Ophthalmol. 2021. PMID: 34571614 Free PMC article.
-
Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery.Eye Vis (Lond). 2016 Jul 29;3:20. doi: 10.1186/s40662-016-0050-x. eCollection 2016. Eye Vis (Lond). 2016. PMID: 27478858 Free PMC article.
-
Characteristics and factors associated with diameter deviation of rhexis reference circle generated by an image-guided system in cataract surgery: a cross-sectional study.Sci Rep. 2024 Dec 30;14(1):31876. doi: 10.1038/s41598-024-83137-5. Sci Rep. 2024. PMID: 39738459 Free PMC article.
-
Perfect anterior capsulorhexis using a dented cystitome.Indian J Ophthalmol. 2021 May;69(5):1311-1313. doi: 10.4103/ijo.IJO_2767_20. Indian J Ophthalmol. 2021. PMID: 33913886 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources