Objective: To prospectively determine the sonographic findings of nodular hyperplasia of the thyroid, to compare these with reported findings associated with malignancy, and to assess interobserver reliability.
Methods: Seventy thyroid nodules were scanned, and then biopsies of the nodules were performed under sonographic guidance with fine-needle cytologic analysis; in all cases images were reviewed by 2 experienced radiologists without knowledge of clinical outcome. Findings reported associated with malignancy were specifically assessed. Interobserver agreement between the expert and secondary readers for each finding was calculated by the kappa or weighted kappa statistic and the Fisher exact test of independence.
Results: There were 68 benign and 2 malignant nodules in a population of 63 female and 7 male patients. The mean benign nodule size was 2.9 cm; 60% were solid; 54% were hypoechoic; 59% were microlobulated or macrolobulated; 47% had central vascularity; 24% contained calcifications; and 82% were elliptical in shape. There was very good interobserver reliability for the presence of calcium (kappa = 0.91) and good agreement for the presence and location of vascularity (kappa = 0.75) and the amount of cystic components (kappa = 0.62; all P < .01).
Conclusions: Sixty-nine percent of benign nodules had at least 1 finding reported previously as associated with malignancy. The interobserver reliability of the sonographic findings was good to very good for 3 of the 5 findings assessed.
Similar articles
-
Risk for malignancy of thyroid nodules as assessed by sonographic criteria: the need for biopsy.J Ultrasound Med. 2004 Nov;23(11):1455-64. doi: 10.7863/jum.2004.23.11.1455. J Ultrasound Med. 2004. PMID: 15498910
-
Peripheral Thyroid Nodule Calcifications on Sonography: Evaluation of Malignant Potential.AJR Am J Roentgenol. 2019 Sep;213(3):672-675. doi: 10.2214/AJR.18.20799. Epub 2019 Jun 5. AJR Am J Roentgenol. 2019. PMID: 31166754
-
Pearls and pitfalls of thyroid nodule sonography and fine-needle aspiration.Ultrasound Q. 2010 Sep;26(3):171-8. doi: 10.1097/RUQ.0b013e3181efa710. Ultrasound Q. 2010. PMID: 20823751
-
Thyroid Ultrasound: Diffuse and Nodular Disease.Radiol Clin North Am. 2020 Nov;58(6):1041-1057. doi: 10.1016/j.rcl.2020.07.003. Epub 2020 Sep 17. Radiol Clin North Am. 2020. PMID: 33040847 Review.
-
Ultrasonographic thyroid findings suspicious for malignancy.Diagn Cytopathol. 2013 Dec;41(12):1107-14. doi: 10.1002/dc.23058. Diagn Cytopathol. 2013. PMID: 24254202 Review.
Cited by
-
Diagnosis of thyroid nodules for ultrasonographic characteristics indicative of malignancy using random forest.BioData Min. 2020 Sep 3;13:14. doi: 10.1186/s13040-020-00223-w. eCollection 2020. BioData Min. 2020. PMID: 32905307 Free PMC article.
-
Real-Time Ultrasonography and the Evaluation of Static Images Yield Different Results in the Assessment of EU-TIRADS Categories.J Clin Med. 2023 Sep 6;12(18):5809. doi: 10.3390/jcm12185809. J Clin Med. 2023. PMID: 37762750 Free PMC article.
-
A Prospective Observational Study Assessing the Relationship Between Solitary Thyroid Nodule Size and Incidence of Malignancy.Cureus. 2020 Nov 10;12(11):e11422. doi: 10.7759/cureus.11422. Cureus. 2020. PMID: 33312818 Free PMC article.
-
The frequency of malignancy and the relationship between malignancy and ultrasonographic features of thyroid nodules with indeterminate cytology.Endocrine. 2014 Feb;45(1):37-45. doi: 10.1007/s12020-013-9922-1. Epub 2013 Mar 17. Endocrine. 2014. PMID: 23504651
-
The National Cancer Institute Thyroid fine needle aspiration state of the science conference: a summation.Cytojournal. 2008 Apr 7;5:6. doi: 10.1186/1742-6413-5-6. Cytojournal. 2008. PMID: 18394201 Free PMC article. No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical