Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart Opiate Microplate EIA and GC-MS following controlled codeine administration
- PMID: 14606992
- DOI: 10.1093/jat/27.7.402
Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart Opiate Microplate EIA and GC-MS following controlled codeine administration
Abstract
Oral fluid specimens (N = 1406) were collected from 19 subjects prior to and up to 72 h following controlled administration of oral codeine. Volunteers provided informed consent to participate in this National Institute on Drug Abuse Institutional Review Board-approved protocol. A modification of Cozart Microplate Opiate EIA Oral Fluid Kit (Opiate ELISA), employing codeine calibrators, was used for semiquantitative analysis of opiates, followed by gas chromatography-mass spectrometry (GC-MS) for the confirmation and quantitation of codeine, norcodeine, morphine, and normorphine in oral fluid. GC-MS limits of detection and quantitation were 2.5 microg/L for all analytes. The Substance Abuse and Mental Health Services Administration (SAMHSA) has proposed a 40-microg/L opiate screening and a 40-microg/L morphine or codeine confirmation cutoff for the detection of opiate use. Oral fluid opiate screening and confirmation cutoffs of 30 micro g/L are in use in the U.K. Utilizing 2.5-, 20-, 30-, and 40-microg/L GC-MS cutoffs, 26%, 20%, 19%, and 18% of the oral fluid specimens were positive for codeine or one of its metabolites. Six Opiate ELISA/confirmation cutoff criteria (2.5/2.5, 10/2.5, 20/20, 30/20, 30/30, and 40/40 microg/L) were evaluated. Calculations for Opiate ELISA sensitivity, specificity, and efficiency were determined from the number of true-positive, true-negative, false-positive, and false-negative results at each screening/confirmation cutoff. Sensitivity, specificity, and efficiency for the lowest cutoff were 91.5%, 88.6%, and 89.3%. Application of the cutoff currently used in the U.K. yielded sensitivity, specificity, and efficiency results of 79.7%, 99.0%, and 95.4% and similar results of 76.7%, 99.1%, and 95.1% when applying the SAMHSA criteria. These data indicate that the Opiate ELISA efficiently detects oral codeine use. In addition, the data, collected following controlled oral codeine administration, may aid in the interpretation of opiate oral fluid test results and in the selection of appropriate oral fluid screening and confirmation cutoffs.
Similar articles
-
Performance characteristics of the Cozart RapiScan Oral Fluid Drug Testing System for opiates in comparison to ELISA and GC/MS following controlled codeine administration.Forensic Sci Int. 2004 Apr 20;141(1):41-8. doi: 10.1016/j.forsciint.2003.12.003. Forensic Sci Int. 2004. PMID: 15066713
-
Cozart RapiScan Oral Fluid Drug Testing System: an evaluation of sensitivity, specificity, and efficiency for cocaine detection compared with ELISA and GC-MS following controlled cocaine administration.J Anal Toxicol. 2003 Oct;27(7):407-11. doi: 10.1093/jat/27.7.407. J Anal Toxicol. 2003. PMID: 14606993
-
Sensitivity and specificity of the Cozart microplate EIA cocaine oral fluid at proposed screening and confirmation cutoffs.Clin Chem. 2003 Sep;49(9):1498-503. doi: 10.1373/49.9.1498. Clin Chem. 2003. PMID: 12928231
-
Hair analysis by immunological methods from the beginning to 2000.Forensic Sci Int. 2000 Jan 10;107(1-3):249-59. doi: 10.1016/s0379-0738(99)00168-1. Forensic Sci Int. 2000. PMID: 10689577 Review.
-
Techniques for improving the specificity of sandwich enzyme-linked immunosorbent assay-based drug screening.Drug Test Anal. 2025 Apr;17(4):555-560. doi: 10.1002/dta.3763. Epub 2024 Jul 2. Drug Test Anal. 2025. PMID: 38956951 Review.
Cited by
-
Drug testing in oral fluid.Clin Biochem Rev. 2006 Aug;27(3):147-59. Clin Biochem Rev. 2006. PMID: 17268583 Free PMC article.
-
Electrochemical Sensor for Methamphetamine Detection Using Laser-Induced Porous Graphene Electrode.Nanomaterials (Basel). 2021 Dec 28;12(1):73. doi: 10.3390/nano12010073. Nanomaterials (Basel). 2021. PMID: 35010025 Free PMC article.
-
Modern instrumental methods in forensic toxicology.J Anal Toxicol. 2007 Jun;31(5):237-53, 8A-9A. doi: 10.1093/jat/31.5.237. J Anal Toxicol. 2007. PMID: 17579968 Free PMC article. Review.
-
Oral fluid testing for drugs of abuse.Clin Chem. 2009 Nov;55(11):1910-31. doi: 10.1373/clinchem.2008.108670. Epub 2009 Sep 10. Clin Chem. 2009. PMID: 19745062 Free PMC article. Review.
-
Mining the salivary proteome with grating-coupled surface plasmon resonance imaging and surface plasmon coupled emission microarrays.Curr Protoc Toxicol. 2012 Aug;Chapter 18:Unit 18.16.1-19. doi: 10.1002/0471140856.tx1816s53. Curr Protoc Toxicol. 2012. PMID: 22896008 Free PMC article.