Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Nov 5;42(9):1574-83.
doi: 10.1016/j.jacc.2003.05.002.

Myocardial strain rate is a superior method for evaluation of left ventricular subendocardial function compared with tissue Doppler imaging

Affiliations
Free article
Comparative Study

Myocardial strain rate is a superior method for evaluation of left ventricular subendocardial function compared with tissue Doppler imaging

Ikuo Hashimoto et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: This study was performed to evaluate subendocardial function using strain rate imaging (SRI).

Background: The subendocardium and mid-wall of the left ventricle (LV) play important roles in ventricular function. Previous methods used for evaluating this function are either invasive or cumbersome. Strain rate imaging by ultrasound is a newly developed echocardiographic modality based on tissue Doppler imaging (TDI) that allows quantitative assessment of regional myocardial wall motion.

Methods: We examined eight sheep using TDI in apical four-chamber views to evaluate the LV free wall. Peak strain rates (SRs) during isovolumic relaxation (IR), isovolumic contraction (IC), and myocardial strain were measured in the endocardial (End), mid-myocardial (Mid), and epicardial (Epi) layers. For four hemodynamic conditions (created after baseline by blood, dobutamine, and metoprolol infusion), we compared differences in SR of End, Mid, and Epi layers to peak positive and negative first derivative of LV pressure (dP/dt).

Results: Strain rate during IC showed a good correlation with +dP/dt (r = 0.74, p < 0.001) and during IR with -dP/dt (r = 0.67, p = 0.0003). There was a significant difference in SR between the myocardial layers during both IC and IR (End: -3.4 +/- 2.2 s(-1), Mid: -1.8 +/- 1.5 s(-1), Epi: -0.63 +/- 1.0 s(-1), p < 0.0001 during IC; End: 2.2 +/- 1.5 s(-1), Mid: 1.0 +/- 0.8 s(-1), Epi: 0.47 +/- 0.64 s(-1), p < 0.0001 during IR). Also, SRs of the End and Mid layers during IC were significantly altered by different hemodynamic conditions (End at baseline: 1.7 +/- 0.7 s(-1); blood: 2.0 +/- 1.1 s(-1); dobutamine: 3.4 +/- 2.3 s(-1); metoprolol: 1.0 +/- 0.4 s(-1); p < 0.05). Myocardial strain showed differences in each layer (End: -34.3 +/- 12.6%; Mid: -22.6 +/- 12.1%; Epi: -11.4 +/- 7.9%; p < 0.0001) and changed significantly in different hemodynamic conditions (p < 0.0001).

Conclusions: Strain and SR appear useful and sensitive for evaluating myocardial function, especially for the subendocardial region.