Electrokinetic characterization of poly(dimethylsiloxane) microchannels
- PMID: 14613192
- DOI: 10.1002/elps.200305624
Electrokinetic characterization of poly(dimethylsiloxane) microchannels
Abstract
This paper characterizes the basic electrokinetic phenomena occurring within native poly(dimethylsiloxane) (PDMS) microchannels. Using simple buffers and current measurements, current density and electroosmosis data were determined in trapezoidal, reversibly sealed PDMS/PDMS and hybrid PDMS/glass channels with a cross-sectional area of 1035.5 microm(2) and about 6 cm length. This data was then compared to that obtained in an air-thermostated 50 microm inner diameter (1963.5 microm(2) cross-sectional area) fused-silica (FS) capillary of 70 cm length. Having a pH 7.8 buffer with an ionic strength (I) of 90 mM, Ohms's law was observed in the microchannels with electric field strengths of up to about 420 V/cm, which is about twice as high as for the FS capillary. The electroosmotic mobility (micro(EO)) in PDMS and FS is shown to exhibit the same general dependences on I and pH. For all configurations tested, the experimentally determined micro(EO) values were found to correlate well with the relationship micro(EO) = a + b log(I), where a and b are coefficients that are determined via nonlinear regression analysis. Electroosmotic fluid pumping in native PDMS also follows a pH dependence that can be estimated with a model based upon the ionization of silanol. Compared to FS, however, the magnitude of the electroosmotic flow in native PDMS is 50-70% smaller over the entire pH range and is difficult to maintain at acidic pH values. Thus, the origin of the negative charge at the inner wall of PDMS, glass, and FS appears to be similar but the density is lower for PDMS than for glass and FS.
Similar articles
-
Modeling of electroosmotic and electrophoretic mobilization in capillary and microchip isoelectric focusing.J Chromatogr A. 2007 Jul 6;1155(2):154-63. doi: 10.1016/j.chroma.2007.01.121. Epub 2007 Feb 6. J Chromatogr A. 2007. PMID: 17307189
-
Electroosmotic flow in poly(dimethylsiloxane) microchannels.J Chromatogr A. 2005 Dec 16;1099(1-2):203-6. doi: 10.1016/j.chroma.2005.11.004. Epub 2005 Nov 21. J Chromatogr A. 2005. PMID: 16303131
-
Poly(oxyethylene) based surface coatings for poly(dimethylsiloxane) microchannels.Langmuir. 2005 Aug 2;21(16):7551-7. doi: 10.1021/la0510432. Langmuir. 2005. PMID: 16042494
-
Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies.Electrophoresis. 2003 Nov;24(21):3563-76. doi: 10.1002/elps.200305584. Electrophoresis. 2003. PMID: 14613181 Review.
-
Surface modification of poly(dimethylsiloxane) microchannels.Electrophoresis. 2003 Nov;24(21):3607-19. doi: 10.1002/elps.200305627. Electrophoresis. 2003. PMID: 14613185 Review.
Cited by
-
Isolation of target DNA using synergistic magnetic bead transport and electrokinetic flow.Biomicrofluidics. 2021 Mar 17;15(2):024104. doi: 10.1063/5.0045307. eCollection 2021 Mar. Biomicrofluidics. 2021. PMID: 33763161 Free PMC article.
-
Study on surface properties of PDMS microfluidic chips treated with albumin.Biomicrofluidics. 2009 Oct 12;3(4):44101. doi: 10.1063/1.3243913. Biomicrofluidics. 2009. PMID: 20216963 Free PMC article.
-
Continuous particle separation using pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE).Sci Rep. 2016 Jan 28;6:19911. doi: 10.1038/srep19911. Sci Rep. 2016. PMID: 26819221 Free PMC article.
-
Application of Microfluidic Chips in the Detection of Airborne Microorganisms.Micromachines (Basel). 2022 Sep 22;13(10):1576. doi: 10.3390/mi13101576. Micromachines (Basel). 2022. PMID: 36295928 Free PMC article. Review.
-
A Cost-Effective Microfluidic Device to Teach the Principles of Electrophoresis and Electroosmosis.J Chem Educ. 2023 Jun 20;100(7):2782-2788. doi: 10.1021/acs.jchemed.2c01028. eCollection 2023 Jul 11. J Chem Educ. 2023. PMID: 37455796 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources