The prospects for super-acuity: limits to visual performance after correction of monochromatic ocular aberration
- PMID: 14622350
- DOI: 10.1046/j.1475-1313.2003.00132.x
The prospects for super-acuity: limits to visual performance after correction of monochromatic ocular aberration
Abstract
It has recently been suggested that correction of the monochromatic aberration of the eye could lead to substantial improvements in visual acuity and contrast sensitivity function. After consideration of the best-corrected visual acuity of normal eyes, the optical and neural limits to visual performance are reviewed. It is concluded that, even if current problems with the accuracy of the suggested techniques of aberration correction, through corneal excimer laser ablation or customised contact lenses, can be overcome, changes in monochromatic ocular aberration over time, the continuing presence of chromatic aberration, errors of focus associated with lags and leads in accommodation, and other factors, are likely to result in only minor improvements in the high-contrast acuity performance of most normal eyes being produced by attempted aberration control. Significant gains in contrast sensitivity might, however, be achievable, particularly under mesopic and scotopic conditions when the pupil is large, provided that correct focus can be maintained. In the immediate future, reduction of the high levels of aberration that are currently found in eyes that have undergone refractive surgery and in some abnormal eyes should bring useful benefits.
Similar articles
-
[Optical and physiological limits of wavefront-controlled keratectomy].Ophthalmologe. 2004 May;101(5):521-36; quiz 537. doi: 10.1007/s00347-004-1013-5. Ophthalmologe. 2004. PMID: 15181908 Review. German.
-
Spherical aberration gauge for human vision.Appl Opt. 2010 Oct 20;49(30):5906-13. doi: 10.1364/AO.49.005906. Appl Opt. 2010. PMID: 20962957
-
Feasibility of spherical aberration correction with aspheric intraocular lenses in cataract surgery based on individual pupil diameter.J Cataract Refract Surg. 2009 Oct;35(10):1725-33. doi: 10.1016/j.jcrs.2009.05.031. J Cataract Refract Surg. 2009. PMID: 19781467
-
Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes.Ophthalmology. 2006 Oct;113(10):1807-12. doi: 10.1016/j.ophtha.2006.03.061. Epub 2006 Jul 31. Ophthalmology. 2006. PMID: 16876865
-
Effect of ocular chromatic aberration on monocular visual performance.Optom Vis Sci. 1991 Aug;68(8):599-607. doi: 10.1097/00006324-199108000-00005. Optom Vis Sci. 1991. PMID: 1923336 Review.
Cited by
-
Adaptive optics technology for high-resolution retinal imaging.Sensors (Basel). 2012 Dec 27;13(1):334-66. doi: 10.3390/s130100334. Sensors (Basel). 2012. PMID: 23271600 Free PMC article. Review.
-
Modulation transfer function of intraocular collamer lens with a central artificial hole.Graefes Arch Clin Exp Ophthalmol. 2011 Jul;249(7):1081-5. doi: 10.1007/s00417-010-1602-8. Epub 2011 Jan 13. Graefes Arch Clin Exp Ophthalmol. 2011. PMID: 21229257
-
Bright Light Therapy and Circadian Cycles in Institutionalized Elders.Front Neurosci. 2020 May 6;14:359. doi: 10.3389/fnins.2020.00359. eCollection 2020. Front Neurosci. 2020. PMID: 32435176 Free PMC article.
-
This issue at a glance.J Curr Ophthalmol. 2016 Aug 18;28(3):99-100. doi: 10.1016/j.joco.2016.07.006. eCollection 2016 Sep. J Curr Ophthalmol. 2016. PMID: 27579451 Free PMC article. No abstract available.
-
[Optical and physiological limits of wavefront-controlled keratectomy].Ophthalmologe. 2004 May;101(5):521-36; quiz 537. doi: 10.1007/s00347-004-1013-5. Ophthalmologe. 2004. PMID: 15181908 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical