Abstract
Background: Laser ablation of placental vessels effectively halts severe twin-to-twin transfusion syndrome (TTTS), but fetal surgery remains a dangerous approach. The authors present the technical aspects of endoscopic fetal surgery in their initial clinical experience.
Methods: Altogether, 11 women underwent endoscopic fetal surgery for severe TTTS. Access to the recipient's sac was obtained by the Seldinger technique via minilaparotomy. A 12-Fr peel-away introducer was used as a cannula to accommodate a custom-curved 9-Fr sheath containing a 1.9-mm semirigid fiber endoscope. Laser ablation was performed on all unpaired vessels crossing the intertwin membrane using a 400- micro m neodymium: yttrium-aluminum-garnet (Nd: YAG) fiber. The cannula was removed over a gelatin sponge plug.
Results: The median operating time was 65 min (range, 45-105 min). No patient experienced amniotic leak postoperatively. The length of hospital stay was 2.8 +/- 1.6 days. Immediate improvement of the TTTS was noted in all but two patients. Pneumonia developed, in one mother leading to premature labor. There were no other major surgical complications. Fetal survival at 2 weeks was 73%.
Conclusions: The safety and efficacy of endoscopic fetal surgery for severe TTTS can be optimized with the application of current minimal-access techniques. The superiority of this approach over less invasive means is still being evaluated through prospective studies.
Similar articles
-
Laser ablation of placental vessels in twin-to-twin transfusion syndrome: a paradigm for endoscopic fetal surgery.J Laparoendosc Adv Surg Tech A. 2011 Nov;21(9):869-72. doi: 10.1089/lap.2011.0119. Epub 2011 Aug 19. J Laparoendosc Adv Surg Tech A. 2011. PMID: 21854207
-
The pediatric surgeons' contribution to in utero treatment of twin-to-twin transfusion syndrome.Ann Surg. 2009 Sep;250(3):456-62. doi: 10.1097/SLA.0b013e3181b45794. Ann Surg. 2009. PMID: 19644353
-
Severe twin-twin transfusion syndrome: outcome after fetoscopic laser ablation of the placental vascular equator.BJOG. 2007 Jun;114(6):689-93. doi: 10.1111/j.1471-0528.2007.01336.x. BJOG. 2007. PMID: 17516959
-
[Twin-to-twin transfusion syndrome: diagnosis and treatment].Bull Acad Natl Med. 2008 Nov;192(8):1575-86; discussion 1586-7. Bull Acad Natl Med. 2008. PMID: 19445374 Review. French.
-
Laser treatment in twin-to-twin transfusion syndrome.Semin Fetal Neonatal Med. 2007 Dec;12(6):450-7. doi: 10.1016/j.siny.2007.07.005. Epub 2007 Oct 22. Semin Fetal Neonatal Med. 2007. PMID: 17950680 Review.
Cited by
-
Anesthesia for fetal operative procedures: A systematic review.Front Pain Res (Lausanne). 2022 Sep 12;3:935427. doi: 10.3389/fpain.2022.935427. eCollection 2022. Front Pain Res (Lausanne). 2022. PMID: 36246050 Free PMC article. Review.
-
Doppler imaging using spectrally-encoded endoscopy.Opt Express. 2008 Sep 15;16(19):14836-44. doi: 10.1364/oe.16.014836. Opt Express. 2008. PMID: 18795020 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources