The accuracy of the GlucoWatch G2 biographer in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study
- PMID: 14633344
- PMCID: PMC2302793
- DOI: 10.1089/152091503322526996
The accuracy of the GlucoWatch G2 biographer in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study
Abstract
The accuracy of the GlucoWatch G2 Biographer (GW2B; Cygnus, Inc., Redwood City, CA) was assessed in children and adolescents with type 1 diabetes mellitus (T1DM). During a 24-h clinical research center stay, 89 children and adolescents with T1DM (3.5-17.7 years old) wore 174 GW2Bs and had frequent serum glucose determinations during the day and night and during insulin-induced hypoglycemia and meal-induced hyperglycemia, resulting in 3672 GW2B-reference glucose pairs. The median relative absolute difference between the GW2B and reference glucose values was 16% (25th, 75th percentiles = 7%, 29%). The proposed International Organisation for Standardisation criteria were met for 60% of sensor values. Accuracy was better at higher serum glucose levels than low glucose levels. Accuracy degraded slightly as the sensor aged. Time of day, subject age, gender, or body mass index did not impact GW2B accuracy. There were no cases of serious skin reactions. Although the accuracy of this generation of sensor does not approach that of current home glucose meters, the majority of sensor glucose values are within 20% of the serum glucose. This level of accuracy may be sufficient for detecting trends and modifying diabetes management. Further longitudinal outpatient studies are needed to assess the utility of the GW2B as a management tool to improve glycemic control and decrease the incidence of severe hypoglycemia in children with diabetes.
References
-
- Centers for Disease Control and Prevention. National Health and Nutrition Examination Survey. BMI-for-age charts, 2 to 20 years, LMS parameters and selected smoothed BMI percentiles, by sex and age. 2000. [Accessed March 2003]. Available from http://www.cdc.gov/nchs/about/major/nhanes/growthcharts/datafiles.htm.
-
- Draize JH. The Appraisal of Chemicals in Food, Drugs, and Cosmetics, Dermal Toxicity. Association of food and drug officials of the United States; Topeka, Kansas: 1965. pp. 45–59.
-
- Neese J, Duncan P, Bayse D, Robinson M, Cooper T, Stewart C. Development and evaluation of a hexokinase/glucose-6-phosphate dehydrogenase procedure for use as a national reference method. HEW Publication No. (CDC) Atlanta: Centers for Disease Control; 1976. pp. 77–8330.
-
- Passey RB, Gillum RL, Fuller JB, Urry FM, Giles ML. Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974) Clin Chem. 1977;23(1):131–9. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
- U10 HD041906/HD/NICHD NIH HHS/United States
- RR06022/RR/NCRR NIH HHS/United States
- M01 RR000069/RR/NCRR NIH HHS/United States
- M01 RR000059/RR/NCRR NIH HHS/United States
- U10 HD041919/HD/NICHD NIH HHS/United States
- U01 HD041890/HD/NICHD NIH HHS/United States
- U10 HD041915/HD/NICHD NIH HHS/United States
- M01 RR00069/RR/NCRR NIH HHS/United States
- RR00059/RR/NCRR NIH HHS/United States
- U10 HD041890/HD/NICHD NIH HHS/United States
- HD041890/HD/NICHD NIH HHS/United States
- M01 RR000070/RR/NCRR NIH HHS/United States
- RR00070-41/RR/NCRR NIH HHS/United States
- M01 RR006022/RR/NCRR NIH HHS/United States
- HD041919-0/HD/NICHD NIH HHS/United States
- U10 HD041918/HD/NICHD NIH HHS/United States
- HD041915/HD/NICHD NIH HHS/United States
- U10 HD041908/HD/NICHD NIH HHS/United States
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous