Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Nov 15;63(22):7870-5.

Near-infrared optical imaging of epidermal growth factor receptor in breast cancer xenografts

Affiliations
  • PMID: 14633715

Near-infrared optical imaging of epidermal growth factor receptor in breast cancer xenografts

Shi Ke et al. Cancer Res. .

Abstract

The specificity of a novel epidermal growth factor (EGF)-Cy5.5 fluorescent optical probe in the detection of EGF receptor (EGFr) was assessed using continuous-wave fluorescence imaging accomplished via an intensified charge-coupled device (CCD) camera. Human mammary MDA-MB-468 (EGFr+) and MDA-MB-435 (EGFr-) cancer cells were incubated with Cy5.5, EGF-Cy5.5, or the anti-EGFr monoclonal antibody C225 or EGF followed by EGF-Cy5.5 and examined under a fluorescence microscope. In vivo imaging was performed on mice with s.c. MDA-MB-468 and MDA-MB-435 tumors. Images were obtained every 6 s for 20 min after i.v. injection of each agent and every 24 h after injection for up to 192 h. Additionally, mice with MDA-MB-468 tumors were injected i.v. with C225 24 h before injection of EGF-Cy5.5. EGF-Cy5.5, but not Cy5.5 or indocyanine green dye (ICG), bound to MDA-MB-468 cells. Binding of EGF-Cy5.5 was blocked by C225 and by EGF. In contrast, binding of EGF-Cy5.5 to MDA-MB-435 cells was not observed. Monitoring of the time-fluorescence intensity in mice confirmed that ICG and Cy5.5 had no favorable binding to tumor regardless of EGFr expression level. In contrast, EGF-Cy5.5 accumulated only in MDA-MB-468 tumors. Moreover, tumor uptake of EGF-Cy5.5 was blocked by C225. ICG and Cy5.5 fluorescence was completely absent from the tumor site, regardless of EGFr expression level, 24 h after injection. Little EGF-Cy5.5 fluorescence was detected in MDA-MB-435 tumors 24 h after injection. In MDA-MB-468 tumors, our data suggest that EGF-Cy5.5 may be used as a specific NIR contrast agent for noninvasive imaging of EGFr expression and monitoring of responses to molecularly targeted therapy.

PubMed Disclaimer

Publication types

MeSH terms