Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Dec;42(6):721-8.
doi: 10.1016/s0196-0644(03)00660-7.

Incidence of transient hypoxia and pulse rate reactivity during paramedic rapid sequence intubation

Affiliations
Comparative Study

Incidence of transient hypoxia and pulse rate reactivity during paramedic rapid sequence intubation

James V Dunford et al. Ann Emerg Med. 2003 Dec.

Abstract

Study objective: We determine the incidence of desaturation and pulse rate reactivity during paramedic rapid sequence intubation of patients with severe head injuries (Glasgow Coma Scale score <or=8).

Methods: Adult patients with severe head injuries had recording oximeter-capnometers applied before rapid sequence intubation. Desaturation was defined as a reduction in oxygen saturation (Spo(2)) to less than 90% from an initial Spo(2) of greater than or equal to 90% or a decrease from a baseline of less than 90%. Event records were analyzed with emergency medical services (EMS) run sheets and debriefing reports.

Results: Thirty-one (57%) of 54 patients demonstrated desaturation during rapid sequence intubation. Twenty-six (84%) of these 31 events occurred in patients whose initial Spo(2) value with basic airway skills was greater than or equal to 90%. The median duration of desaturation was 160 seconds (interquartile range 48 to 272 seconds), and the median decrease in Spo(2) was 22%. Six (19%) patients experienced marked bradycardia (pulse rate <50 beats/min) during desaturation events. Paramedics described rapid sequence intubation as "easy" in 26 (84%) of 31 patients with desaturation.

Conclusion: Out-of-hospital rapid sequence intubation by paramedics was complicated by a concerning incidence of desaturation and bradycardia. Paramedic reports did not reflect the presence of these concerning derangements. Most patients had acceptable Spo(2) values before rapid sequence intubation. An effective strategy for preoxygenation is needed before it can be concluded that rapid sequence intubation is of value in the out-of-hospital care of patients with serious closed head injury.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Substances