Effect of prosthetic material on adhesion formation after laparoscopic ventral hernia repair in a porcine model
- PMID: 14634842
- DOI: 10.1007/s10029-003-0181-6
Effect of prosthetic material on adhesion formation after laparoscopic ventral hernia repair in a porcine model
Abstract
Intraperitoneal placement of prosthetic mesh causes adhesion formation after laparoscopic incisional hernia repair. A prosthesis that prevents or reduces adhesion formation is desirable. In this study, 21 pigs were randomized to receive laparoscopic placement of plain polypropylene mesh (PPM), expanded polytetrafluoroethylene (ePTFE), or polypropylene coated on one side with a bioresorbable adhesion barrier (PPM/HA/CMC). The animals were sacrificed after 28 days and evaluated for adhesion formation. Mean area of adhesion formation was 14% (SD+/-15) in the PPM/HA/CMC group, 40% (SD+/-17) in the PPM group, and 41% (SD+/-39) in the ePTFE group. The difference between PPM/HA/CMC and PPM was significant ( P=0.013). A new visceral layer of mesothelium was present in seven out of seven PPM/HA/CMC cases, six out of seven PPM cases, and two out of seven ePTFE cases. Thus, laparoscopic placement of PPM/HA/CMC reduces adhesion formation compared to other mesh types used for laparoscopic ventral hernia repairs.
Similar articles
-
A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh.Surg Endosc. 2005 Jun;19(6):786-90. doi: 10.1007/s00464-004-8174-9. Epub 2005 Mar 23. Surg Endosc. 2005. PMID: 15776214
-
Prevention of intraabdominal adhesions produced by polypropylene mesh.Eur Surg Res. 2002 May-Jun;34(3):239-43. doi: 10.1159/000063395. Eur Surg Res. 2002. PMID: 12077511
-
Prevention of adhesion to prosthetic mesh in incisional ventral hernias: comparison of different barriers in an experimental model.Eur Surg Res. 2006;38(3):358-64. doi: 10.1159/000094382. Epub 2006 Jul 4. Eur Surg Res. 2006. PMID: 16825774
-
[The problem of mesh shrinkage in laparoscopic incisional hernia repair].Zentralbl Chir. 2009 Jun;134(3):209-13. doi: 10.1055/s-0028-1098779. Epub 2009 Jun 17. Zentralbl Chir. 2009. PMID: 19536713 Review. German.
-
Ventral hernia repair with synthetic, composite, and biologic mesh: characteristics, indications, and infection profile.Surg Infect (Larchmt). 2012 Aug;13(4):209-15. doi: 10.1089/sur.2012.123. Epub 2012 Aug 22. Surg Infect (Larchmt). 2012. PMID: 22913337 Review.
Cited by
-
Naturally derived and synthetic scaffolds for skeletal muscle reconstruction.Adv Drug Deliv Rev. 2015 Apr;84:208-21. doi: 10.1016/j.addr.2014.08.011. Epub 2014 Aug 29. Adv Drug Deliv Rev. 2015. PMID: 25174309 Free PMC article. Review.
-
Comparative evaluation of adhesions to intraperitoneally placed fixation materials: a laparoscopic study in rats: adhesions to fixation materials.Indian J Surg. 2010 Dec;72(6):475-80. doi: 10.1007/s12262-010-0168-3. Epub 2010 Nov 23. Indian J Surg. 2010. PMID: 22131658 Free PMC article.
-
Infected animal models for tissue engineering.Methods. 2015 Aug;84:17-24. doi: 10.1016/j.ymeth.2015.03.025. Epub 2015 Apr 2. Methods. 2015. PMID: 25843609 Free PMC article. Review.
-
Tissue ingrowth and bowel adhesion formation in an animal comparative study: polypropylene versus Proceed versus Parietex Composite.Surg Endosc. 2007 Apr;21(4):629-33. doi: 10.1007/s00464-006-9157-9. Epub 2007 Feb 7. Surg Endosc. 2007. PMID: 17285369
-
Evaluation of new prosthetic meshes for ventral hernia repair.Surg Endosc. 2006 Aug;20(8):1320-5. doi: 10.1007/s00464-005-0706-4. Epub 2006 Jul 24. Surg Endosc. 2006. PMID: 16865616
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical