In vitro and short-term in vivo characteristics of a Kel-F thin film modified glucose sensor
- PMID: 14640443
- DOI: 10.2116/analsci.19.1481
In vitro and short-term in vivo characteristics of a Kel-F thin film modified glucose sensor
Abstract
A new outer layer composition, consisting of polytetrafluoroethylene (PTFE), Kel-F oil, and Nafion, is suggested to minimize the detrimental effect of dissolved oxygen and to extend the linear response range of a glucose oxidase(GOx)-based sensor using nonconducting polymer. The morphology of Kel-F/PTFE/Kel-F/Nafion polymeric laminate was followed during fabrication by SEM. When Kel-F film was formed on the PTFE outer layer, the linear response was extended to 21 mM, at a sensitivity of 2.8 +/- 0.8 nA/mM mm2. We demonstrate that a sensor without Kel-F/PTFE/Kel-F/Nafion outer layer is relatively oxygen dependent, whereas by comparison a sensor with Kel-F/PTFE/Kel-F/Nafion outer layer is oxygen independent. The current of such a glucose sensor implanted in the subcutaneous tissue stabilized within 60 min, and the lag between blood glucose changes and sensor output was within 1 min. The in vivo characteristics of the glucose sensor described show great promise for one-point in vivo calibration.
Similar articles
-
In vivo calibration of the subcutaneous amperometric glucose sensors using a non-enzyme electrode.Biosens Bioelectron. 2003 Dec 15;19(4):313-9. doi: 10.1016/s0956-5663(03)00219-7. Biosens Bioelectron. 2003. PMID: 14615088
-
Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration.Anal Chem. 1998 May 15;70(10):2149-55. doi: 10.1021/ac970932u. Anal Chem. 1998. PMID: 9608851
-
Preparation of multiwalled carbon nanotubes-platinum-Nafion-glucose oxidase nanobiocomposite and its application to glucose biosensor.J Nanosci Nanotechnol. 2007 Apr-May;7(4-5):1611-7. doi: 10.1166/jnn.2007.344. J Nanosci Nanotechnol. 2007. PMID: 17450933
-
High-performance glucose biosensor based on chitosan-glucose oxidase immobilized polypyrrole/Nafion/functionalized multi-walled carbon nanotubes bio-nanohybrid film.J Colloid Interface Sci. 2016 Nov 15;482:39-47. doi: 10.1016/j.jcis.2016.07.067. Epub 2016 Jul 27. J Colloid Interface Sci. 2016. PMID: 27485503
-
Fabrication of an implantable fine needle-type glucose sensor using gamma-polyglutamic acid.Anal Sci. 2010;26(5):551-5. doi: 10.2116/analsci.26.551. Anal Sci. 2010. PMID: 20467129
Cited by
-
Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.Biointerphases. 2011 Jun;6(2):43-53. doi: 10.1116/1.3583535. Biointerphases. 2011. PMID: 21721839 Free PMC article.
-
Continuous Measurement of Lactate Concentration in Human Subjects through Direct Electron Transfer from Enzymes to Microneedle Electrodes.ACS Sens. 2023 Apr 28;8(4):1639-1647. doi: 10.1021/acssensors.2c02780. Epub 2023 Mar 26. ACS Sens. 2023. PMID: 36967522 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical