Comparison of water and lipid content measurements using diffuse optical spectroscopy and MRI in emulsion phantoms
- PMID: 14640767
- DOI: 10.1177/153303460300200608
Comparison of water and lipid content measurements using diffuse optical spectroscopy and MRI in emulsion phantoms
Abstract
We present a quantitative comparison of lipid and water signals obtained from broadband Diffuse Optical Spectroscopy (DOS) and Magnetic Resonance Imaging (MRI). DOS and MRI measurements were performed on an identical set of emulsion phantoms that were composed of different water/soybean oil fractions. Absolute concentrations of water and lipid ranging from 35-94% and 63-6%, respectively were calculated from quantitative broadband near-infrared (NIR) absorption spectra (650-1000 nm). MR images of fat and water were separated using the three-point Dixon technique. DOS and MRI measured water and lipid were highly correlated (R(2) = 0.98 and R(2) = 0.99, respectively) suggesting that these techniques are complementary over a broad range of physiologically relevant water and lipid values. In addition, comparison of DOS derived concentrations to the MRI "gold standard" technique validates our quantitation approach and permits estimation of DOS accuracy and sensitivity in vivo.
Similar articles
-
Multifrequency frequency-domain spectrometer for tissue analysis.Rev Sci Instrum. 2009 Feb;80(2):024301. doi: 10.1063/1.3082024. Rev Sci Instrum. 2009. PMID: 19256664
-
Estimation of lipid and water concentrations in scattering media with diffuse optical spectroscopy from 900 to 1,600 nm.J Biomed Opt. 2010 May-Jun;15(3):037015. doi: 10.1117/1.3454392. J Biomed Opt. 2010. PMID: 20615044
-
In vivo water state measurements in breast cancer using broadband diffuse optical spectroscopy.Phys Med Biol. 2008 Dec 7;53(23):6713-27. doi: 10.1088/0031-9155/53/23/005. Epub 2008 Nov 7. Phys Med Biol. 2008. PMID: 18997265 Free PMC article.
-
The role of diffuse optical spectroscopy in the clinical management of breast cancer.Dis Markers. 2003-2004;19(2-3):95-105. doi: 10.1155/2004/460797. Dis Markers. 2003. PMID: 15096707 Free PMC article. Review.
-
Study of Minor Chromophores in Biological Tissues by Diffuse Optical Spectroscopy (Review).Sovrem Tekhnologii Med. 2025;17(1):146-162. doi: 10.17691/stm2025.17.1.12. Epub 2025 Feb 28. Sovrem Tekhnologii Med. 2025. PMID: 40071075 Free PMC article. Review.
Cited by
-
Narrowband diffuse reflectance spectroscopy in the 900-1000 nm wavelength region to quantify water and lipid content of turbid media.Biomed Opt Express. 2021 May 4;12(6):3091-3102. doi: 10.1364/BOE.425451. eCollection 2021 Jun 1. Biomed Opt Express. 2021. PMID: 34221647 Free PMC article.
-
Noninvasive optical imaging of resistance training adaptations in human muscle.J Biomed Opt. 2017 Dec;22(12):1-9. doi: 10.1117/1.JBO.22.12.121611. J Biomed Opt. 2017. PMID: 29264896 Free PMC article.
-
Establishing the feasibility and reliability of broadband absorption spectroscopy for measuring cerebral water content in adults.Biomed Opt Express. 2025 Feb 25;16(3):1187-1196. doi: 10.1364/BOE.551192. eCollection 2025 Mar 1. Biomed Opt Express. 2025. PMID: 40109518 Free PMC article.
-
VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance.Diagnostics (Basel). 2023 Jan 26;13(3):457. doi: 10.3390/diagnostics13030457. Diagnostics (Basel). 2023. PMID: 36766562 Free PMC article.
-
Anthropomorphic breast phantoms with physiological water, lipid, and hemoglobin content for near-infrared spectral tomography.J Biomed Opt. 2014 Feb;19(2):026012. doi: 10.1117/1.JBO.19.2.026012. J Biomed Opt. 2014. PMID: 24549438 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous