Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Dec;110(12):2342-8.
doi: 10.1016/S0161-6420(03)00733-4.

Dynamic morphology of clear corneal cataract incisions

Affiliations
Free article

Dynamic morphology of clear corneal cataract incisions

Peter J McDonnell et al. Ophthalmology. 2003 Dec.
Free article

Abstract

Objective: Clear corneal cataract incisions without sutures allow for rapid visual rehabilitation after phacoemulsification but might be associated with an increased risk of postoperative infection. The goal of this study was to examine in vitro dynamic changes in unhealed clear corneal cataract incisions that might adversely affect the risk of intraocular infection.

Design: Laboratory investigation.

Methods: Self-sealing clear corneal incisions were created in cadaveric human and rabbit eyes, and intraocular pressure was controlled with an infusion cannula. Incisions were imaged in real time using optical coherence tomography as intraocular pressure was varied. Using an artificial anterior chamber, India ink was applied to the surface of cadaveric human corneas with clear corneal incisions to detect possible flow of surface fluid along the incision. Intraocular pressure was varied by raising and lowering the infusion bottle so as to simulate the variation in intraocular pressure that would occur with successive blinks.

Results: Optical coherence tomography demonstrated variation of corneal wound morphology in response to changes in intraocular pressure. Higher intraocular pressures were associated with close apposition of the wound edges, with no tendency for wound leakage. At low intraocular pressures, however, wound edges tended to gape, starting at the internal aspect of the wound. One incision opened along the entire length, allowing fluid flow across the cornea. Histologic examination revealed India ink particles in all incisions for up to three fourths of the length of the wound.

Conclusions: Transient reduction of intraocular pressure might result in poor wound apposition in clear corneal incisions, with the potential for fluid flow across the cornea and into the anterior chamber, with the attendant risk of endophthalmitis.

PubMed Disclaimer

Comment in

  • Morphology of clear cataract incisions.
    Wong MY. Wong MY. Ophthalmology. 2004 Apr;111(4):849; author reply 849. doi: 10.1016/j.ophtha.2004.01.011. Ophthalmology. 2004. PMID: 15051226 No abstract available.

Publication types