High-resolution scanning electron microscopy of frozen-hydrated cells
- PMID: 1464901
- DOI: 10.1111/j.1365-2818.1992.tb03259.x
High-resolution scanning electron microscopy of frozen-hydrated cells
Abstract
Cryo-fixed yeast Paramecia and sea urchin embryos were investigated with an in-lens type field-emission SEM using a cold stage. The goal was to further develop and investigate the processing of frozen samples for the low-temperature scanning electron microscope (LTSEM). Uncoated frozen-hydrated samples were imaged with the low-voltage backscattered electron signal (BSE). Resolution and contrast were sufficient to visualize cross-fractured membranes, nuclear pores and small vesicles in the cytoplasm. It is assumed that the resolution of this approach is limited by the extraction depth of the BSE which depends upon the accelerating voltage of the primary beam (V0). In this study, the lowest possible V0 was 2.6 kV because below this value the sensitivity of the BSE detector is insufficient. It is concluded that the resolution of the uncoated specimen could be improved if equipment were available for high-resolution BSE imaging at 0.5-2 kV. Higher resolution was obtained with platinum cryo-coated samples, on which intramembranous particles were easily imaged. These images even show the ring-like appearance of the hexagonally arranged intramembranous particles known from high-resolution replica studies. On fully hydrated samples at high magnification, the observation time for a particular area is limited by mass loss caused by electron irradiation. Other potential sources of artefacts are the deposition of water vapour contamination and shrinkage caused by the sublimation of ice. Imaging of partially dehydrated (partially freeze-dried) samples, e.g. high-pressure frozen Paramecium and sea urchin embryos, will probably become the main application in cell biology. In spite of possible shrinkage problems, this approach has a number of advantages compared with any other electron microscopy preparation method: no chemical fixation is necessary, eliminating this source of artefacts; due to partial removal of the water additional structures in the cytoplasm can be investigated; and finally, the mass loss due to electron beam irradiation is greatly reduced compared to fully frozen-hydrated specimens.
Similar articles
-
Scanning electron microscopy of high-pressure-frozen sea urchin embryos.Scanning Microsc. 1993 Dec;7(4):1283-92; discussion 1292-3. Scanning Microsc. 1993. PMID: 8023095
-
Progress in scanning electron microscopy of frozen-hydrated biological specimens.Scanning Microsc. 1993 Mar;7(1):343-9; discussion 349-50. Scanning Microsc. 1993. PMID: 8316804
-
Backscattered electron imaging for high resolution surface scanning electron microscopy with a new type YAG-detector.Scanning Microsc. 1991 Jun;5(2):301-9; discussion 310. Scanning Microsc. 1991. PMID: 1947922
-
Double-layer coating for field-emission cryo-scanning electron microscopy--present state and applications.Scanning. 1997 Aug;19(5):343-8. doi: 10.1002/sca.4950190501. Scanning. 1997. PMID: 9262018 Review.
-
Low-temperature scanning electron microscopy in biology.J Microsc. 1991 Jan;161(Pt 1):59-72. doi: 10.1111/j.1365-2818.1991.tb03073.x. J Microsc. 1991. PMID: 2016738 Review.
Cited by
-
Scalable substrate development for aqueous sample preparation for atom probe tomography.J Microsc. 2025 Aug;299(2):104-117. doi: 10.1111/jmi.13255. Epub 2023 Dec 28. J Microsc. 2025. PMID: 38115688 Free PMC article.
-
Exploring the nuclear envelope of herpes simplex virus 1-infected cells by high-resolution microscopy.J Virol. 2009 Jan;83(1):408-19. doi: 10.1128/JVI.01568-08. Epub 2008 Oct 15. J Virol. 2009. PMID: 18922868 Free PMC article.
-
Extending Cryo-EM to Nonaqueous Liquid Systems.Acc Chem Res. 2021 May 4;54(9):2100-2109. doi: 10.1021/acs.accounts.1c00077. Epub 2021 Apr 19. Acc Chem Res. 2021. PMID: 33871969 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous