Central venous catheter dressings: a systematic review
- PMID: 14651685
- DOI: 10.1046/j.0309-2402.2003.02852.x
Central venous catheter dressings: a systematic review
Abstract
Background: Gauze and tape or transparent polyurethane film dressings such as Tegaderm, Opsite or Opsite IV3000 are the most common types of dressing used to secure central venous catheters (CVCs). Currently, there are no clear guidelines as to which type of dressing is the most appropriate.
Aims: To identify whether there are any differences between gauze and tape and/or transparent polyurethane film dressings in the incidence of CVC-related infection, catheter-related sepsis, catheter security, tolerance to dressing material, dressing condition and ease of application in hospitalized patients.
Methods: The Cochrane Controlled Trials Register and Medline, Embase and CancerLit databases were searched to identify any controlled trials comparing the effects of gauze and tape and/or transparent polyurethane dressings on CVCs. Additional references were sought from published and non-published literature. Twenty-three studies were reviewed. Data were extracted independently from each paper by two members of the review team and results compared. Differences were resolved either by consensus or referral to a third person. Authors were contacted for missing information.
Results: Of the 23 studies reviewed, 15 were excluded. Of the remaining eight, data were available for meta-analysis from six studies. Of the six included studies, two compared gauze and tape with Opsite IV3000, two compared Opsite with Opsite IV3000, one compared Tegaderm with Opsite IV3000, and one compared Tegaderm with Opsite.
Conclusions: There was no evidence of any difference in the incidence of infectious complications between any of the dressing types compared in this review. Each of these comparisons was based on no more than two studies and all of these studies reported data from a small patient sample. Therefore it is unlikely that any of these comparisons would have had sufficient power to detect any differences between groups.
Similar articles
-
Gauze and tape and transparent polyurethane dressings for central venous catheters.Cochrane Database Syst Rev. 2003;(4):CD003827. doi: 10.1002/14651858.CD003827. Cochrane Database Syst Rev. 2003. Update in: Cochrane Database Syst Rev. 2011 Nov 09;(11):CD003827. doi: 10.1002/14651858.CD003827.pub2. PMID: 14583995 Updated.
-
Gauze and tape and transparent polyurethane dressings for central venous catheters.Cochrane Database Syst Rev. 2011 Nov 9;(11):CD003827. doi: 10.1002/14651858.CD003827.pub2. Cochrane Database Syst Rev. 2011. Update in: Cochrane Database Syst Rev. 2016 May 04;(5):CD003827. doi: 10.1002/14651858.CD003827.pub3. PMID: 22071809 Updated.
-
Hydrogel dressings for venous leg ulcers.Cochrane Database Syst Rev. 2022 Aug 5;8(8):CD010738. doi: 10.1002/14651858.CD010738.pub2. Cochrane Database Syst Rev. 2022. PMID: 35930364 Free PMC article.
-
Dressings and topical agents for treating venous leg ulcers.Cochrane Database Syst Rev. 2018 Jun 15;6(6):CD012583. doi: 10.1002/14651858.CD012583.pub2. Cochrane Database Syst Rev. 2018. PMID: 29906322 Free PMC article.
-
Dressings and topical agents for the management of open wounds after surgical treatment for sacrococcygeal pilonidal sinus.Cochrane Database Syst Rev. 2022 May 20;5(5):CD013439. doi: 10.1002/14651858.CD013439.pub2. Cochrane Database Syst Rev. 2022. PMID: 35593897 Free PMC article.
Cited by
-
[Operation and management guidelines for peripherally inserted central catheter in neonates (2021)].Zhongguo Dang Dai Er Ke Za Zhi. 2021 Mar;23(3):201-212. doi: 10.7499/j.issn.1008-8830.2101087. Zhongguo Dang Dai Er Ke Za Zhi. 2021. PMID: 33691911 Free PMC article. Chinese.
-
Guidelines for the prevention of intravascular catheter-related infections: recommendations relevant to interventional radiology for venous catheter placement and maintenance.J Vasc Interv Radiol. 2012 Aug;23(8):997-1007. doi: 10.1016/j.jvir.2012.04.023. J Vasc Interv Radiol. 2012. PMID: 22840801 Free PMC article. No abstract available.
-
Comparing test methods for moisture-vapor transmission rate (MVTR) for vascular access transparent semipermeable dressings.J Vasc Access. 2021 Oct 8;24(5):11297298211050485. doi: 10.1177/11297298211050485. Online ahead of print. J Vasc Access. 2021. PMID: 34622681 Free PMC article.
-
Focus on peripherally inserted central catheters in critically ill patients.World J Crit Care Med. 2014 Nov 4;3(4):80-94. doi: 10.5492/wjccm.v3.i4.80. eCollection 2014 Nov 4. World J Crit Care Med. 2014. PMID: 25374804 Free PMC article. Review.
-
Guidelines for the prevention of intravascular catheter-related infections.Clin Infect Dis. 2011 May;52(9):e162-93. doi: 10.1093/cid/cir257. Epub 2011 Apr 1. Clin Infect Dis. 2011. PMID: 21460264 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical