On the use of LiF:Mg,Ti thermoluminescence dosemeters in space--a critical review
- PMID: 14653322
- DOI: 10.1093/oxfordjournals.rpd.a006337
On the use of LiF:Mg,Ti thermoluminescence dosemeters in space--a critical review
Abstract
The use of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) in space radiation fields is reviewed. It is demonstrated in the context of modified track structure theory and microdosimetric track structure theory that there is no unique correlation between the relative thermoluminescence (TL) efficiency of heavy charged particles, neutrons of all energies and linear energy transfer (LET). Many experimental measurements dating back more than two decades also demonstrate the multivalued, non-universal, relationship between relative TL efficiency and LET. It is further demonstrated that the relative intensities of the dosimetric peaks and especially the high-temperature structure are dependent on a large number of variables, some controllable, some not. It is concluded that TL techniques employing the concept of LET (e.g. measurement of total dose, the high-temperature ratio (HTR) methods and other combinations of the relative TL efficiency of the various peaks used to estimate average Q or simulate Q-LET relationships) should be regarded as lacking a sound theoretical basis, highly prone to error and, as well, lack of reproducibility/universality due to the absence of a standardised experimental protocol essential to reliable experimental methodology.
Similar articles
-
Efficiency-corrected dose verification with thermoluminescence dosemeters in heavy-ion beams.Radiat Prot Dosimetry. 2006;120(1-4):361-4. doi: 10.1093/rpd/nci581. Epub 2006 May 18. Radiat Prot Dosimetry. 2006. PMID: 16709709
-
Dosimetry of densely ionising radiation with three LiF phosphors for space applications.Radiat Prot Dosimetry. 2006;120(1-4):397-400. doi: 10.1093/rpd/nci674. Epub 2006 May 26. Radiat Prot Dosimetry. 2006. PMID: 16731689
-
LiF:Mg,Ti (MTT) TL detectors optimised for high-LET radiation dosimetry.Radiat Meas. 2004 Aug-Dec;38(4-6):427-30. doi: 10.1016/j.radmeas.2003.12.013. Radiat Meas. 2004. PMID: 15856580
-
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.Radiat Prot Dosimetry. 2004;109(4):331-48. doi: 10.1093/rpd/nch310. Radiat Prot Dosimetry. 2004. PMID: 15273352 Review.
-
Past and future application of solid-state detectors in manned spaceflight.Radiat Prot Dosimetry. 2006;120(1-4):387-96. doi: 10.1093/rpd/ncj014. Epub 2006 Jun 9. Radiat Prot Dosimetry. 2006. PMID: 16766573 Review.
Cited by
-
Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100).Radiat Prot Dosimetry. 2008;131(4):406-13. doi: 10.1093/rpd/ncn197. Epub 2008 Jul 29. Radiat Prot Dosimetry. 2008. PMID: 18667402 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources